Heatiator IDV4833IT Indoor Fireplace User Manual


 
Heatilator • ICON DV-IDV Series • 4042-575 • Rev. S • 5/11 43
1 in. (25 mm) min.
to perpendicular wall
A
7.75 in. (159 mm) min.
from fireplace opening
to perpendicular wall
B
Mantel Leg or
Perpendicular Wall
Top of
Appliance
Drywall
A
B
Measured from top of fireplace opening (in inches)
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
11-1/2
12-1/4
13
13-3/4
14-1/2
15-1/4
16
16-3/4
17-1/2
18-1/4
19
19-3/4
20-1/2
21-1/4
22
22-3/4
30 in. minimum
to ceiling
1
2
10
10-3/4
14
14
Finishing
A. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as speci ed. Framing or nishing
material closer than the minimums listed must be construct-
ed entirely of non-combustible materials (i.e., steel studs,
concrete board, etc).
Figure 14.1 Minimum Vertical and Maximum Horizontal Dimen-
sions
Figure 14.2 Mantel Leg or Wall Projections (Acceptable on both
sides of opening)
Mantels
Mantel Legs or Wall Projections
0 in.
0 in.
0 in.
Finish wall material may be combustible - Top and Sides
High Temperature Sealant (300° F/149° C min.)
Top and Side Seal Joint
A
B
Shaded area -
noncombustible
materials only
AB
inches 44 3/8 46 1/2
mm 1127 1181
inches 48 7/8 60 1/2
mm 1241 1537
IDV4833
IDV6247
Model
B. Facing Material
Metal front faces may be covered with non-combustible
materials only.
• Facing and/or nishing materials must not interfere with
air ow through louvers, operation of louvers or doors,
or access for service.
• Facing and/or nishing materials must never overhang
into the glass opening.
Observe all clearances when applying combustible
materials.
Seal joints between the nished wall and appliance top
and sides using a 300°F minimum sealant. Refer to
Figure 14.3.
WARNING! Risk of Fire! DO NOT apply combustible ma-
terials beyond the minimum clearances. Comply with all
minimum clearances to combustibles as speci ed in this
manual. Overlapping materials could ignite and will inter-
fere with proper operation of doors and louvers.
Figure 14.3 Non-combustible Facing Diagram