Heatiator HEIR42T Indoor Fireplace User Manual


 
33
Heatilator •
HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12
F. PVK-80 and PVI-SLP Information
This section provides speci c detail for installation of
HEIR36, HEIR42, and HEIR50 models with approved
power vent kits. Follow instructions included with the
PVK-80 or PVI-SLP power vent kits.
See Table 7.1 below for approved Power Venting options
for HEIR models.
WARNING! Risk of Fire! Use ONLY Hearth & Home
Technologies-approved power venting systems with this
appliance. Use of power venting systems not approved
by Hearth & Home Technologies may cause replace to
overheat.
The power vent draft ow must be adjusted and set per
the speci cations in Table 7.2. Refer to the instructions
provided with the PVK-80 and PVI-SLP for more speci c
information.
PVK-80: The exhaust control lever reduces the draft as it
is opened. Open the exhaust control lever to FULL OPEN.
See Figure 7.10. Secure the exhaust control lever to the
power vent housing with the sheet metal screw.
PVI-SLP: The baf e adjustment is measured using the
holes on the indicator bar of the PVI-SLP baf e. This bar
raises as the baf e is opened and lowers as the baf e is
closed. Adjust the baf e by turning the screw located in
the motor enclosure. See Figure 7.11 and 7.12.
PVK-80
Exhaust Control
Lever
PVI-SLP
Baf e Adjustment
Setting
HEIR36 FULL OPEN 3 Holes Visible
HEIR42 FULL OPEN 3 Holes Visible
HEIR50 FULL OPEN 3 Holes Visible
Table 7.2
Figure 7.11 Baf e Adjustment Location - PVI-SLP
ADJUSTMENT BOLT
INDICATOR BAR
INDICATOR BAR
ADJUSTMENT HOLES
Figure 7.12 Baf e Adjustment - PVI-SLP
Figure 7.10 PVK-80 Control Lever Adjustment - Open
Table 7.1
WARNING! Risk of Explosion! Follow instructions to
set draft ow. Incorrect setting may impair burner perfor-
mance and/or cause delayed ignition.
EXHAUST CONTROL LEVER
EXHAUST CONTROL LEVER
PVK-80 PVI-SLP
HEIR36 APPROVED APPROVED
HEIR42 APPROVED APPROVED
HEIR50 APPROVED APPROVED