Heatiator HEIR42T Indoor Fireplace User Manual


 
13
Heatilator •
HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12
L. After Fireplace is Lit
Initial Break-in Procedure
• The fireplace should be run three to four hours
continuously on high.
• Turn the replace off and allow it to completely cool.
• Remove xed glass assembly. See Section 14.H.
• Clean xed glass assembly. See Section 3.
• Replace the xed glass assembly and run continuously
on high an additional 12 hours.
This cures the materials used to manufacture the re-
place.
NOTICE! Open windows for air circulation during re-
place break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
M. Frequently Asked Questions
ISSUE SOLUTIONS
Condensation on the glass
This is a result of gas combustion and temperature variations. As the replace warms, this
condensation will disappear.
Blue ames
This is a result of normal operation and the ames will begin to yellow as the replace is al-
lowed to burn for 20 to 40 minutes.
Odor from replace
When rst operated, this replace may release an odor for the rst several hours. This is caused
by the curing of the paint and the burning off of any oils remaining from manufacturing. Odor may
also be released from nishing materials and adhesives used around the replace.
Film on the glass
This is a normal result of the curing process of the paint and logs. Glass should be cleaned
within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing
process. A non-abrasive cleaner such as gas replace glass cleaner may be necessary. See
your dealer.
Metallic noise
Noise is caused by metal expanding and contracting as it heats up and cools down, similar to
the sound produced by a furnace or heating duct. This noise does not affect the operation or
longevity of the replace.
Is it normal to see the pilot ame burn
continually?
In an intermittent pilot ignition system (IPI), the pilot ame should turn off when appliance is
turned off. Some optional control systems available with IPI models may allow pilot ame to
remain lit.
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
22 IN.
34 IN.
40 IN.
46 IN.
52 IN. MIN.
CEILING
28 IN.
APPLIANCE FRONT
FIREPLACE OPENING
165°F+
150°F
160°F
155°F
160°F
NOTE: TEMPERATURES OF THE
NON-COMBUSTIBLE BOARD ABOVE
THE APPLIANCE EXCEED 180°F.
10 IN.
180F+
230°F+
16 IN.
Figure 2.5 Wall Surface Temperatures