Heatiator HEIR42T Indoor Fireplace User Manual


 
20
Heatilator • HEIR36, HEIR42, HEIR50 • 2285-900 Rev. D • 8/12
C
B
D
A
B. Constructing the Appliance Chase
A chase is a vertical box-like structure built to enclose the
gas appliance and/or its vent system. In cooler climates
the vent should be enclosed inside the chase.
NOTICE: Treatment of ceiling restops and wall shield
restops and construction of the chase may vary with the
type of building. These instructions are not substitutes
for the requirements of local building codes. Therefore,
you MUST check local building codes to determine the
requirements to these steps.
Chases should be constructed in the manner of all out-
side walls of the home to prevent cold air drafting prob-
lems. The chase should not break the outside building
envelope in any manner.
Walls, ceiling, base plate and cantilever oor of the chase
should be insulated. Vapor and air in ltration barriers
should be installed in the chase as per regional codes for
the rest of the home. Additionally, in regions where cold
air in ltration may be an issue, the inside surfaces may be
sheetrocked and taped for maximum air tightness.
To further prevent drafts, the wall shield and ceiling re-
stops should be caulked with caulk with a minimum of
Figure 5.2 Clearances to Combustibles
C. Clearances
NOTICE: Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly
on carpeting, vinyl, tile or any combustible material other
than wood.
WARNING! Risk of Fire! Maintain speci ed air space
clearances to appliance and vent pipe:
Insulation and other materials must be secured to prevent
accidental contact.
• The chase must be properly blocked to prevent blown
insulation or other combustibles from entering and
making contact with replace or chimney.
Failure to maintain airspace may cause overheating and
a re.
300ºF continuous exposure rating to seal gaps. Gas
line holes and other openings should be caulked with
caulk with a minimum of 300ºF continuous exposure rating
or stuffed with unfaced insulation. If the appliance is being
installed on a cement surface, a layer of plywood may be
placed underneath to prevent conducting cold up into the
room.
* Adjust framing dimensions for interior sheathing (such as sheetrock)
F
H
G
I
J
E
(FROM APPLIANCE
OPENING TO CEILING)
* MINIMUM FRAMING DIMENSIONS
ABCDE F GHIJ
Rough
Opening
(Vent Pipe)
Rough
Opening
(Height)
Rough
Opening
(Depth)
Rough
Opening
(Width)
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
Behind
Appliance
Sides of
Appliance
Front of
Appliance
HEIR36
Inches 10 56 24 59-1/2 52 0
See
Section
5.E.
1136
Millimeters 254 1422 610 1511 1321 0 25 25 914
HEIR42
Inches 10 61 24 65-9/16 52 0 1 1 36
Millimeters 254 1549 610 1665 1321 0 25 25 914
HEIR50
Inches 10 65 24 73-9/16 52 0 1 1 36
Millimeters 254 1651 610 1868 1321 0 25 25 914