Heat & Glo LifeStyle TWILIGHT-II Indoor Fireplace User Manual


 
Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05 19
Outside Facing Material
Fire Risk.
Finish all edges and fronts to clearances and
specifications listed in manual.
WARNING
Black metal columns may be covered with non-
combustible material only.
Do NOT overlap combustible materials onto
appliance front.
Install combustible materials up to specified clear-
ances on top front and side edges.
Seal joints between the finished wall and appliance
top and sides using only a 300
o
F minimum sealant.
Figure 8.3 Exterior View
COMBUSTIBLE
SHEATHING
HOUSEWRAP
NON-COMBUSTIBLE
SHEATHING
NON-
COMBUSTIBLE
FACING
6 INCH MAXIMUM
PROJECTION FROM
FACE OF APPLIANCE
6 IN.
MAX.
REQUIRED
HOOD
(SUPPLIED WITH
TL-TRIM KIT)
BRICK
LEDGE
12 IN.
REQUIRED
FLASHING
(SUPPLIED WITH
TL-TRIM KIT)
NON-COMBUSTIBLE
SHEATHING
12 IN.
HOUSE
WRAP
THERE MUST BE NO GAP
BETWEEN BRICK LEDGE,
FACING MATERIAL AND
APPLIANCE FRONT.
Î
May install non-combustible materials to cover gap be-
tween facing material and appliance (see Figure 8.3).
Fire Risk.
Water Intrusion Risk.
TL-TRIM Kit with hood is required.
WARNING
TL-TRIM Kit must be installed on
exterior before flashing and facing.
Í