Heat & Glo LifeStyle TWILIGHT-II Indoor Fireplace User Manual


 
Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/0514
A. Recommendation for Wire
This appliance requires 110-120 VAC be wired to the
junction box for proper operation of the appliance.
Electrical Information
7
NOTE: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA 70-
latest edition or the Canadian Electric Code, CSA C221.1.
B. Connecting to the Appliance
WARNING
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
Incorrect wiring will damage millivolt valves.
Incorrect wiring will override IPI safety
lockout and may cause explosion.
This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
If using thermostat use one compatible with a millivolt
gas valve system.
Follow parameters for locating thermostat (see individual
thermostat instructions) to ensure proper operation of
appliance.
Keep wire lengths short as possible by removing any
excess wire length.
Low voltage and 110 VAC voltage cannot be shared within
the same wall box.
NOTE: Waterproof insulated wire should be used when
wiring the junction box.
CAUTION
Label all wires prior to disconnection when servicing con-
trols. Wiring errors can cause improper and dangerous op-
eration. Verify proper operation after servicing.
Shock hazard.
Replace damaged wire with type 105
O
C
rated wire.
Wire must have high temperature insulation.
CAUTION