Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12
RED JUMPER
WIRE TO
BROWN
WHITE
ORANGE
INTERMITTENT
PILOT IGNITOR
IGNITION MODULE
3 VAC
REMOTE RECEIVER
ORANGE
GREEN
BLACK
RED
VALVE
GROUND TO
FIREPLACE CHASSIS
TRANSFORMER
3 VAC
PLUG
IN
ORANGE
ORANGE
RED
RED
FLAME
CONTROL
SOLENOID
BATTERY PACK
I
S
RED
RED
ORANGE
ORANGE
BRN
ORANGE
ORANGE
BRN
PIGGYBACK
ON/OFF SWITCH
RED
RED
BRN
REMOTE
RECEIVER
Figure 8.31 Remote Control IPI Wiring Diagram
Wiring the flame control solenoid:
Connect the two leads from the flame control solenoid to
the orange leads from the receiver. See Figure 8.31.
Install a manometer into the pressure tap. Plug the remote
receiver into the 110-120 VAC power supply.
Light the appliance as directed in Section 9 of this manual.
Set the manifold pressure on the gas valve by rotating the
flame control solenoid. Adjust until the reading on the
manometer is 3.5 in. W.C. for natural gas or 10 in. W.C.
for LP.
Tighten the jam nut to the face of the variable regulator
body. See Figure 8.30. Turn the main gas knob on the gas
valve OFF. Remove the manometer from the pressure tap
and screw the tap closed.
Follow the instructions from the remote control kit to
operate and program the remote control.