Heat & Glo LifeStyle PALOMA-BZ-MOD Indoor Fireplace User Manual


 
29
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12
Figure 7.2
NOTE: Appliance will not operate
unless properly grounded.
*
TRANSFORMER
3 VAC
PLUG IN
VALVE
GROUND TO
APPLIANCE CHASSIS
PIGGYBACK
ON/OFF SWITCH
INTERMITTENT
PILOT IGNITOR
IGNITION MODULE
3 VAC
I
S
WHT
ORG
RED
ORG
BRN
GRN
BRN
BLACK
BATTERY
PACK
GROUND
REMOTE
CONTROL
HOT
NEUTRAL
VALVE
PLUG-IN 3V
TRANSFORMER
ON/OFF
WALL
SWITCH
IGNITION
MODULE
(3V)
FLAME
SPARKER/SENSOR
JUNCTION BOX
BATTERY LOCATION
Unplug when
using batteries
Figure 7.3
D. Loss of Power and Battery Backup Usage
1. Disconnect the power supply.
2. Remove the front door assembly and lower access
panel.
3. Place two "D" cell batteries into the battery holder.
(Figure 7.3)
4. Turn on appliance and verify it is operational.
5. Replace lower access panel and front door assembly.
CAUTION
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Shock hazard.
Replace damaged wire with type 105º C rated
wire.
Wire must have high temperature insulation.
WARNING
CAUTION
If IPI battery back-up is installed:
Do not install batteries if the backup mode may not be used
for extended time.
• Batteries may leak.
• Install batteries only when needed for power outage.