Heat & Glo LifeStyle 6100PLUS Indoor Fireplace User Manual


 
8 Hearth & Home Technologies • 6100PLUS • 4041-127 Rev D • 09/05
C. Clearances
1 in. (25 mm) min.
to perpendicular wall
A
3-1/2 in. (89 mm) min.
from fireplace opening
to perpendicular wall
B
48 in.
(1219 mm)
max.
Mantel Leg or
Perpendicular Wall
Top of
Appliance
Drywall
A
B
Figure 3.4 Clearances to Mantel Legs or Wall Projections (Accept-
able on both sides of opening)
0 in.
1/2 in.
(13 mm)
32-7/8 in.
(835 mm)
0 in.
to floor
0 in. to combustibles
in front of the FAF
23-1/2 in.
(597 mm)
38-3/4 in.
(984 mm)
42 in.
(1067 mm)
Figure 3.2 Clearances to Combustibles
Measured from top of fireplace opening (in inches)
3
4
5
6
7
8
9
10
11
12
10-3/4
13-3/4
13-3/4
13-3/4
16-3/4
16-3/4
16-3/4
19-3/4
19-3/4
19-3/4
32-7/8 in. minimum
to ceiling
Figure 3.3 Clearances to Mantels or Other Combustibles Above
Appliance
D. Mantel Projections