Heat & Glo LifeStyle 6100PLUS Indoor Fireplace User Manual


 
Hearth & Home Technologies • 6100PLUS • 4041-127 Rev D • 09/05 7
B. Construct the Appliance Chase
A chase is a vertical boxlike structure built to enclose the gas
appliance and/or its vent system. Vertical vents that run on
the outside of a building may be, but are not required to be,
installed inside a chase.
Construction of the chase may vary with the type of build-
ing. These instructions are not substitutes for the require-
ments of local building codes. Local building codes MUST
be checked.
Chases should be constructed in the manner of all outside
walls of the home to prevent cold air drafting problems. The
chase should not break the outside building envelope in any
manner.
Walls, ceiling, base plate and cantilever fl oor of the chase
should be insulated. Vapor and air infi ltration barriers should
be installed in the chase as per regional codes for the rest of
the home. Additionally, in reagions where cold air infi ltration
may be an issure, the inside surfaces be sheetrocked and
taped for maximum air tightness.
To further prevent drafts, the ceiling fi restops should be
caulked with high temperature caulk to seal gaps. Gas line
holes and other openings should be caulked with high tem-
perature caulk or stuffed with unfaced insulation. If the appli-
ance is being installed on a cement slab, a layer of plywood
may be placed underneath to prevent conducting cold up
into the room.
Fire Risk
Odor Risk
Install appliance on hard metal or wood
surfaces extending full width and depth
of appliance.
Do NOT install appliance directly on
carpeting, vinyl, tile or any combustible
material other than wood.
WARNING
Fire Risk
Construct chase to all clearance
specifi cations in manual.
Locate and install appliance to all
clearance specifi cations in manual.
WARNING