Heat Controller R-410A Heat Pump User Manual


 
15
REFRIGERANT CHARGING TABLES - COOLING MODE
Shaded boxes indicate flooded conditions.
Rated design values are based on rated indoor air flow and 80 °F entering dry bulb.
1. Suction pressure will vary according to variations in indoor conditions.
2 All pressures are listed psig and all temperatures in °F
3. Discharge temperatures greater than charted values indicate an undercharged system.
Table 7. Charging Table for G48K Series (4 Ton)
4 TON MODELS
Suct.
PreSS.
OutDOOr teMPerAture (° F)
70 75 80 85 90 95 100 105
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
133 280 143
135
282 149
305 147
137 285 154
307 152
330 151
139
290 153
309 157
332 156
355 155
141 293 156
314 158
334 160
357 159
380 158
143 318 161
339 163
359 164
382 163
405 163
145 342 166
363 167
384 167
407 167
430 167
147 367 170
388 171
409 171
432 171
455 171
149 370 174 391 175
412 175
434 175
457 175
151 395 179 416 179
437 179
459 178
153 419 183 440 183
461 183
155 444 187 465 187
157 468 191
159
Table 8. Charging Table for G60 Series (5 Ton)
5 TON MODELS
Suc.
PreSS.
OutDOOr teMPerAture (° F )
70 75 80 85 90 95 100 105
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
124
126 274 101
128
276 112
295 111
130 277 124
298 121
318 119
132
279 129
300 131
320 128
340 128 360 130
134 280 146
303 136
326 128
344 134
363 137 383 136
136 304 150
327 141
350 133
367 145
387 142 406 141
138 329 155
352 145
374 145
391 149
410 148 430 148
140 354 159
376 153
398 148
415 154
434 153
142 378 164
401 158
423 153
439 159
144 403 168
425 163
447 158
146 428 172
450 167
148 452 176
150