Heat Controller R-410A Heat Pump User Manual


 
14
Table 5. Charging Table for G36 Series (3 Ton)
3 TON MODELS
Suct.
P
reSS.
OutDOOr teMPerAture (° F)
70 75 80 85 90 95 100 105
Liq.
P
reSS.
D
iS.
t
eMP.
L
iq.
P
reSS.
D
iS.
t
eMP.
L
iq.
P
reSS.
D
iS.
t
eMP.
L
iq.
P
reSS.
D
iS.
t
eMP.
L
iq.
P
reSS.
D
iS.
t
eMP.
L
iq.
P
reSS.
D
iS.
t
eMP.
L
iq.
P
reSS.
D
iS.
t
eMP.
L
iq.
P
reSS.
D
iS.
t
eMP.
132
134 265 116
136
266 127
286 122
138 268 138
288 132
308 128
140
268 155
291 142
311 136
330 134 348 135
142 269 172
292 156
314 144
333 140
352 142 370 140
144 293 171
315 157
337 146
356 150
374 146 392 144
146 317 171
339 158
360 156
378 153
396 151 414 150
148 340 173
362 164
383 158
401 157
418 156
150 364 175
385 168
406 162
423 161
152 387 177
408 171
429 166
154 410 180
431 175
156 434 184
158
REFRIGERANT CHARGING TABLES - COOLING MODE
Shaded boxes indicate flooded conditions.
Rated design values are based on rated indoor air flow and 80 °F entering dry bulb.
1. Suction pressure will vary according to variations in indoor conditions.
2 All pressures are listed psig and all temperatures in °F
3. Discharge temperatures greater than charted values indicate an undercharged system.
Table 6. Charging Table for G42 Series (3.5 Ton)
3.5 TON MODELS
Suct.
PreSS.
OutDOOr teMPerAture (° F)
70 75 80 85 90 95 100 105
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
Liq.
PreSS.
DiS.
teMP.
134 269 129
136
271 135
293 134
138 274 140
295 139
316 138
140
279 139
297 144
318 143
340 143
142 282 142
302 145
320 148
342 148
363 148
144 305 148
325 150
344 152
365 152
387 153
146 328 154
348 155
367 156
389 157
410 157
148 351 159
371 160
391 161
412 161
434 162
150 355 163 374 164
394 165
414 165
436 166
152 378 168 398 169
417 170
438 170
154 401 173 421 174
440 174
156 424 178 444 179
158 447 183
160