Hearth and Home Technologies MBK Indoor Fireplace User Manual


 
SAVE THESE INSTRUCTIONS
www.quadrafire.com
This manual contains instructions for Installation, Operation & Maintenance.
Please read this entire manual before you install and use your new room heater. Failure to follow
instructions may result in property damage, bodily injury, or even death.
Yosemite
Non-Catalytic, Front/Side Load, Wood Heater
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
7004-187F September 1, 2008
IMPORTANT SAFETY NOTES:
1) When installing your stove, particular attention should be paid to fire protection. If this room heater is not properly installed,
a house fire may result. To reduce the risk of fire, follow the installation instructions. Contact local building or fire officials or
authority having jurisdiction about restrictions, installation inspection and permit requirements in your area.
2) CAUTION: Never use gasoline or gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen
up” a fire in this heater. Keep all such liquids well away from heater while it is in use.
3) During operation, if any part of the stove starts to glow, the stove is in an overfired condition. Close the air controls completely
until the glowing has stopped. OVERFIRING VOIDS YOUR WARRANTY!
4) Cool ashes should be disposed of carefully, using a metal container.
5) Do not burn wet or green wood. Store wood in a dry location.
6) DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL. Do not burn
treated wood, or wood with salt (driftwood, etc.). Burning materials other than wood (including charcoal) under adverse
conditions may generate carbon monoxide in the home, resulting in illness or possible death.
7) Do not permit creosote or soot to accumulate excessively in the chimney or inside the firebox.
8) Check your chimney system thoroughly when installing into an existing metal or masonry chimney. Seek professional
advice if in doubt about its condition.
9) Do not connect this unit to a chimney flue already serving another appliance.
10) Comply with all minimum clearances to combustibles as shown in this manual for this appliance.
11) Build fire on brick firebox floor. Do not use grates, andirons or other methods to support fuel.
12) HOT WHILE IN OPERATION! Keep children, pets, clothing and furniture away. Contact can cause skin burns.
13) Do not connect to any air distribution duct or system.
14) RISK OF FIRE! Do not operate with stove door open without the firescreen or with the ash removal system door open.
15) For further information refer to NFPA 211 (USA) or CAN/CSA-B365 (Canada).
16) Do not operate without fully assembling all components.
17) Do not operate with broken glass.
1445 North Highway
Colville, WA 99114-2008
PRIOR TO FIRST FIRE: Remove all labels from glass. Clean plated surfaces with a glass cleaner and soft cloth
to prevent staining from fingerprint oils.