Hearth and Home Technologies SL-550TRS-IPI-E Indoor Fireplace User Manual


 
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/07 7
K
C
A
L
F
I
B
G
E
D
J
J
G
A
F
C
A
H
M
N
In addition to these framing dimensions, also reference the following sections:
Clearances and Mantel Projections (Section 3.C and 3.D)
Vent Clearances and Framing (Section 6).
3
3
Framing and Clearances
Note:
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
Fire Risk
Provide adequate clearance:
Around air openings
• To combustibles
• For service access
Locate appliance away from traf c areas.
A. Selecting Appliance Location
When selecting a location for your appliance it is important to
consider the required clearances to walls (see Figure 3.1).
Figure 3.1 Appliance Locations
NOTE: For actual appliance dimensions refer to Sec-
tion 16.
WARNING
Models A B C D
E
Min.
F
Min.
GH I JKLM N
SL-750TRS-IPI-E
in. 45-1/2 42 64-3/8
See Section
E for Alcove
Installation
1 1/2 45-1/2 64-3/8 16-1/4 48-1/2 68-3/4 16-5/8 7-1/2 9
mm 1155 1067 1635 25 13 1155 1635 413 1232 1737 422 191 229
SL-550TRS-IPI-E
in. 42 37 59-1/2 1 1/2 44 62-1/4 16-1/4 48-1/2 68-3/4 15-1/16 7-1/2 7-1/8
mm 1067 940 1511 25 13 1117 1581 413 1232 1737 383 191 181
SL-350TRS-D
in. 39-1/2 34 55-7/8 1 1/2 44 62-1/4 16-1/4 48-1/2 68-3/4 13-1/2 7-1/2 6
mm 1003 864 1413 25 13 1117 1581 413 1232 1737 343 191 152