Hearth and Home Technologies SL-550TRS-IPI-E Indoor Fireplace User Manual


 
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/0724
Figure 5.15
Two Elbows
H
1
Maximum V
1
Minimum H
2
H
1
+ H
2
Maximum
1-1/2 ft. 457 mm
Back to Back
Elbows
1 ft. 305 mm 2-1/2 ft. 762 mm
3-1/2 ft. 1.1 m 1 ft. 305 mm 3 ft. 914 mm 6-1/2 ft. 2.0 m
5-1/2 ft. 1.2 m 2 ft. 610 mm 5 ft. 1.5 m 10-1/2 ft. 3.2 m
7-1/2 ft. 2.3 m 3 ft. 914 mm 7 ft. 2.1 m 14-1/2ft. 4.4 m
H
1
Maximum = 7-1/2 ft. (2.3 m)
V
1
+ V
2
+ H
1
+ H
2
Maximum = 40 ft. (12.2 m)
4. Rear Vent - Vertical Termination - (continued)
H
1
+ H
2
Maximum V
1
Minimum
1/2 ft. 152 mm Back to Back Elbows
2-1/2 ft. 762 mm 1 ft. 305 mm
4-1/2 ft. 1.4 m 2 ft. 610 mm
6-1/2 ft. 2.0 m 3 ft. 914 mm
H Maximum = 6-1/2 ft. (2 m)
V
1
+ H
1
+ H
2
Maximum = 40 ft. (12.2 m)
Figure 5.16
Three Elbows
Note: Use DVP Series
components only.
Note: Use DVP Series
components only.
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
V
2
V
1
H
2
H
1