Hearth and Home Technologies SL-550TRS-IPI-E Indoor Fireplace User Manual


 
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/07 23
3. Rear Vent - Horizontal Termination - (continued)
Figure 5.13
Figure 5.14
Three Elbows
H
1
Maximum V
1
Minimum H
2
+ H
3
H
1
+ H
2
+ H
3
Maximum
1-1/2 ft. 457 mm
Back to Back
Elbows
1 ft. 305 mm 2-1/2 ft. 762 mm
3-1/2 ft. 1.1 m 1 ft. 305 mm 2 ft. 610 mm 5-1/2 ft. 1.7 m
5-1/2 ft. 1.7 m 2 ft. 610 mm 4 ft. 1.2 m 9-1/2 ft. 2.9 m
7-1/2 ft. 2.3 m 3 ft. 914 mm 6 ft. 1.8 m
13-1/2
ft.
4.1 m
H
1
Maximum = 7-1/2 ft. (2.3 m)
H
1
+ H
2
+ H
3
Maximum =13-1/2 ft. (4.1 m)
V
1
+ H
1
+ H
3
= 40 ft. (12.2 m)
V
1
H
1
One Elbow
V
1
Minimum H
1
Maximum
Elbow Only 1-1/2 ft. 457 mm
1 ft. 305 mm 3-1/2 ft. 1.1 m
2 ft. 610 mm 5-1/2 ft. 1.7 m
3 ft. 914 mm 7-1/2 ft. 2.3 m
H
1
Maximum = 7-1/2 ft. (2.3 m)
V
1
+ H
1
Maximum = 40 ft. (12.2 m)
4. Rear Vent - Vertical Termination
Note: Use DVP Series
components only.
Note: Use DVP Series
components only.
INSTALLED
HORIZONTALLY
H
3
H
1
H
2
V
1