Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI • 2006-901 Rev. C • 12/07
30
Step 4. Positioning, Leveling, and Securing
the Fireplace
• Place the fireplace into position.
• Level the fireplace from side to side and from front to
back.
• Shim the fireplace with non-combustible material, such
as sheet metal, as necessary.
• Secure the fireplace to the framing by nailing or screwing.
• Holes are provided in the base pan for securing the unit
to the floor.
!
The diagram below shows how to properly position, level,
and secure the fireplace.
Figure 31. Proper Positioning, Leveling, and
Securing of a Fireplace
Step 5. The Gas Control System
WARNING: THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.
Figure 32. Gas Control System
IPI PILOT
!
WARNING: CONTINUOUS 110-120 VAC
SERVICE MUST BE WIRED DIRECTLY TO
THE FIREPLACE JUNCTION BOX IN A IPI SYSTEM.
Intermittent Pilot Ignition (IPI) System
This system includes a 3V control valve, electronic module
and intermittent pilot.
FLAME
SENSOR
ROD
NAILING
TA BS
(BOTH SIDES)