Hearth and Home Technologies Heat & Glo Gas Heater User Manual


 
21
Heat & Glo • 6000TRSI-AUC • 2078-900 Rev. G • 12/06
FIGURE 1.33FIGURE 1.32
F. MANTEL CLEARANCES
Clearance to a mantelpiece is 12 inches (305mm). See
Figure 1.32.
NOTE: ALL DIMENSIONS ARE
SHOWN IN MILLIMETERS.
IF JOINTS BETWEEN THE FINISHED WALLS AND
THE FIREPLACE SURROUND (TOP AND SIDES)
ARE SEALED, A 150°
C. MINIMUM SEALANT
MATERIAL MUST BE USED. THESE JOINTS ARE
NOT REQUIRED TO BE SEALED. ONLY NON-
COMBUSTIBLE MATERIAL (USING 150° C.
MINIMUM ADHESIVE, IF NEEDED) CAN BE
APPLIED AS FACING TO THE FIREPLACE
SURROUND. SEE FIGURE 1.33.
0
FINISH WALL MATERIAL MAY BE
COMBUSTIBLE - TOP AND SIDES
0
0
NON-COMBUSTIBLE
BOARD
89
127
152
178
203
254
279
51
76
102
127
305
279
254
229
203
178
152
TOP FRONT EDGE
OF FIREPLACE
38
25
76
102
114
229
NON-COMBUSTIBLE
BOARD
HIGH TEMPERATURE (150
0
C MIN.)
TOP AND SIDE SEAL JOINT