A. Mantel Projections
This appliance is approved to be installed with a clearance
to the ceiling and/or other projections of 12 inch minimum
from the top of the replace (see Figure 11.1).
11
11
Finishing
B. Facing Material
Fire Risk.
Finish all edges and fronts to clearances and
speci cations listed in manual.
• Install combustible materials only up to specified
clearances on top, front and side.
Seal joints between the nished wall and appliance top
and sides using only a 300º F minimum sealant.
Figure 11.1 Clearances to mantels or other combustibles
above appliance
Fire Risk.
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
Modifying or covering grilles could cause
temperature rise and re hazard.
Finishing materials must not interfere with:
• Air ow through grilles or louvers.
Operation of louvers or doors.
Access for service.
WARNING
WARNING
Figure 11.2 Facing Diagram
0 in.
0 in.
0 in.
1-1/2 in.
12 IN. MIN.
TO CEILING
AND/OR MANTEL
TOP OF
UNIT
Sheetrock or other nishing materials can be brought to
within 1-1/2 inch of top of replace and to within 0 inches
on the sides and bottom.