Hearth and Home Technologies 5100I-NL-B Indoor Fireplace User Manual


 
Page 5
5100-I ACT WOOD INSERT
R
438-0380D
September 1, 2008
3. I smell smoke in the house during operation. What is causing it?
Diagnostic Question Possible Causes of Condition Solutions
Do res start and burn well? No:
Chimney obstruction
Not enough kindling and/or fuel
to establish draft
Inadequate combustion air
Air controls not open
Yes:
Competition with exhaust devices
No:
Check & clean chimney if needed
Use adequate kindling & fuel
Open air controls
Open window
Check for need for balanced air
make-up (Outside Air)
Yes:
Do not use exhaust fans during
startup
Check for need for balanced air
make-up (Outside Air)
4. I don’t get enough/any heat. What can I do about it?
Diagnostic Question Possible Causes of Condition Solutions
How much wood is used for re? Insufcient fuel Make larger res
How well seasoned is the wood? Condition of fuel Burn seasoned wood: (split, covered
on top minimum 6 months, preferably
a year)
Is blower operating properly?
Snap disc not working
Is blower plugged in?
Setting to high on blower cooling
rebox.
Replace snap disc
Plug in blower
Turn blower to lower setting
How are air controls set? Operational problems
Follow manufacturer’s instructions
5. The wood burns too fast. What can I do?
Diagnostic Question Possible Causes of Condition Solutions
What is the condition of the wood? Extremely dry wood Mix in less seasoned wood after re
established
How are air controls set? Operational problems
Follow manufacturer’s instructions
6. The blower does not come on when insert reaches set temperate. What can I do?
Diagnostic Question Possible Causes of Condition Solutions
Is blower operating properly? Snap disc not working Replace snap disc