Installing
Place the stove on a noncombustible floor pro-
tector that extends a minimum of 6 inches to the front,
2 inches to the sides and flush with the rear of the
hopper. See Fig. 6.The minimum floor protector ma-
terial is 20 gauge sheet metal. Other floor protector
materials are ceramic tile, stone, brick, etc.
Place the stove away from combustible walls at
least as far as shown in Figures 3,4 and 5. Please
note the difference in side wall clearance with and
without side shields.
Note that the clearances shown are minimum
for safety but do not leave much room for access
when cleaning or servicing. Please take this into ac-
count when placing the stove.
Connect the power cord to a 120 V.A.C. 60Hz
grounded receptacle. (A surge protector is recom-
mended to protect the circuit board.) If the voltage
entering your home is below 116 volts your stove may
not work properly. Also be sure that the polarity of
the outlet that the stove is plugged into is correct.
Prior to installing the flue pipe, connect a draft
meter. (The draft meter must have a minimum range
of 0-.5.)Record the first reading. Connect flue pipe
to stove and be sure all doors and windows in the
home are closed. Record the second draft read-
ing_______. If the second reading is more than .05"
lower than the first reading, check for possible re-
strictions or the need for outside air (see page 8).
For more information on the draft test procedure, re-
fer to Page 19.
Mobile Home Installation
When installing this unit in a mobile home sev-
eral requirements must be followed:
1. The unit must be bolted to the floor. This can
be done with 1/4" lag screws through the 2 holes in
the base plate.
2. The unit must also be connected to outside
air. See page 8.
3. Floor protection and clearances must be fol-
lowed as shown.
4. Unit must be grounded to the metal frame of
the mobile home.
CAUTION: This appliance must be vented to the
outside.
Due to high temperatures, the stove should be
placed out of traffic and away from furniture and drap-
eries.
Children and adults should be alerted to the haz-
ards of high surface temperatures and should stay
away to avoid burns to skin and/or clothing.
Young children should be carefully supervised
when they are in the same room as the stove.
Clothing and other flammable materials should
not be placed on or near this unit.
Installation and repair of this Harman stove should
be done by a qualified service person. We recommend
that the stove be inspected before use and at least
annually by a qualified service person. Periodic clean-
ing is required throughout the heating season and at
the end of each winter for the stove to work efficiently.
See cleaning instructions on page 21.
Installation
9"-13"
9"-13"
9" With Side Shields
13" Without Side Shields
Floor Protection must be 2 inches to each side, 6
inches to the front, and 0 inches to the back of the
stove. Floor Protector minimum: 25" wide x 33" deep.
Fig. 3
Fig. 4
14"
2"
Fig. 6
2"
6"
0"
(even with
hopper)
Fig. 5
20"
2"
25" minimum
2"
33" minimum