Harman Stove Company P61A Stove User Manual


 
7
P61A Pellet Stove

Place the stove on a noncombustible oor or on a oor
protector that extends a minimum of 6 inches to the front,
(measured from the glass) 6 inches to the sides and 1 inch
to the rear of the hopper. It is also recommended that oor
protection be installed under any horizontal venting and ex-
tending 2 inches beyond the vent measurement. Material used
for oor protection must be a minimum 3/8" of material rated
at 0.84k per inch. Another method for calculating oor protec-
tion is in R-value. Minimum permitted is 0.45 R. Example: 1"
thickness of a material is rated at 0.52 R, which would meet
the requirement.
Place the stove away from combustible walls at least as far
as shown in Figures 3,4 and 5. Note the difference in side wall
clearance with and without side shields.
Note that the clearances shown are minimum for safety
but do not leave much room for access when cleaning or
servicing.
Connect the power cord to a 120 V.A.C. 60Hz grounded
receptacle. (A surge protector is recommended to protect the
circuit board.) Also be sure that the polarity of the outlet that
the stove is plugged into is correct.
Prior to installing the ue pipe, connect a draft meter. (The
draft meter must have a minimum range of 0-.5.) Record the
rst reading. Connect ue pipe to stove and be sure all doors
and windows in the home are closed. Record the second
draft reading_______. If the second reading is more than .05"
lower than the rst reading, check for possible restrictions or
the need for outside air (see page 9). For more information
on the draft test procedure, refer to Page 21.

When installing this unit in a mobile home, several require-
ments must be followed:
1. The unit must be bolted to the oor. This can be done with
1/4" lag screws through the 2 holes in the base plate.
2. The unit must also be connected to outside air. See page
9.
3. Floor protection and clearances must be followed as
shown.
4. Unit must be grounded to the metal frame of the mobile
home.











Fig. 4
9" With Side Shields
13" Without Side Shields
Fig. 3
9" or 13"
9" or 13"
Fig. 6
Fig. 5
18"


