Harman Stove Company P61A Stove User Manual


 
11
P61A Pellet Stove

This method also provides excellent venting
for normal operation but requires the stove to be
installed farther from the wall. The vertical portion
of the vent should be three to ve feet high and at
least three inches from a combustible wall. This
vertical section will provide natural draft in the event
of a power failure.
If the stove is installed below grade be sure the
vent termination is at least 18" above grade. The
outlet must also be 1 foot from the house/building.







This method provides excellent venting for
normal operation and allows the stove to be in-
stalled closest to the wall. Two inches from the wall
is safe; however, four inches allows better access
to remove the rear panel. The vertical portion of the
vent should be three to ve feet high. This vertical
section will help provide natural draft in the event of
a power failure. 


Fig. 8
3 ft.
to combustibles
Fig. 9
3 ft.
to combustibles
3 ft.
to combustibles
36" min
clearance to any
combustible
material
12" min. wall to outlet
3 ft.
to combustibles