Harman Stove Company P61A Stove User Manual


 
14
P61A Pellet Stove

Through the ceiling vent, follow PL vent
manufacturers recommendations when using wall
and ceiling pass through. 

Fig. 14
PL vent manufacturer's
firestop spacer and
support
(See Page 7 for
corner installation
clearances)
  

It is recommended that outside
air be installed with this venting
conguration to reduce smoke
and creosote smell in the room
in the event of power failure.
Min. above ground level
18"
Storm collar
Flashing
3" min.
3" min.
12" min.
3" min.

Fig. 15
3" min.
No insulation or
other combustible
m a t e r i al s a r e
allo we d with in
3" of the pellet
vent pipe. Unless
specified by the
pipe manufacturer
12" min. wall to outlet
36" min clearance to any
combustible material
Fig. 16