Harbor Freight Tools 92274 Water Pump User Manual


 
SKU 92274 For technical questions, please call 1-800-444-3353. PAGE 11
C. Power Cord may not be making contact in electrical outlet. Check connec-
tion.
D. Float may be obstructed. Make sure the Float is free and not rubbing against
the pit wall or other obstruction.
3. Pump Motor Runs, but does not discharge water.
A. Check Valve (not included) may be installed backwards or is defective.
Check to make sure it is installed properly and flapper in valve is free to
move.
B. Discharge Pipe may be frozen or blocked. Check to see if Discharge Pipe
passes through cold areas or is blocked.
C. Sump Pump may be airlocked. Check to see if air bleed hole is open.
D. Vertical lift is beyond Sump Pump’s capability. Maximum lift capability is 17
feet.
E. Inlet screen of Sump Pump is blocked, or Impeller is jammed. Remove Pump
and clean inlet screen and Impeller.
4. Pump Motor runs and discharges water, but will not shut off.
A. Float is stuck in the “ON” position. Check to make sure Float is free to move
up and down without interference.
B. Switch is not working. Have a qualified service technician replace Switch.
5. Pump Motor runs, but delivers small amount of water.
A. Vertical lift is approaching Sump Pump’s maximum lift capability. Maximum
lift capability is 17 feet. Reduce height of vertical lift.
B. Inlet is partially blocked. Check to make sure inlet is clear of debris.
C. Discharge Pipe is partially blocked. Check Pipe for blockage.
D. Check Valve is not opening all the way. Check for defective or blocked Check
Valve.
6. Circuit breaker trips or fuse blows when Sump Pump starts.
A. Breaker or fuse size is too small. A minimum 15 AMP breaker or fuse should
be used.
B. Other major appliances are on the same circuit. Sump Pump should be on its
own separate circuit.
C. Sump Pump is connected to an extension cord, or wiring is inadequate. DO
NOT USE EXTENSION CORDS. Have a certified electrician check
for proper wiring.
D. Switch or Motor not working. Have a qualified service technician check
Switch and Motor for proper operation.
B. Water level in pit may be too low (Switch has not yet activated). Add more
water to pit.