Goodmans GPC1324H41A Air Conditioner User Manual


 
37
COOLING PERFORMANCE DATA
5MM COILS
GPC1336H41AB
MODEL: GPC1336H41A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 34.5 35.8 39.2 - 33.7 34.9 38.3 - 32.9 34.1 37.3 - 32.1 33.3 36.4 - 30.5 31.6 34.6 - 28.2 29.3 32.1 -
S/T 0.74 0.62 0.43 - 0.77 0.64 0.45 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.85 0.71 0.49 -
Delta T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 16 14 11 -
1350 KW 2.53 2.59 2.66 - 2.72 2.78 2.86 - 2.89 2.95 3.04 - 3.03 3.10 3.20 - 3.16 3.23 3.33 - 3.26 3.34 3.44 -
AMPS 10.9 11.1 11.4 - 11.6 11.9 12.2 - 12.5 12.7 13.1 - 13.2 13.5 13.9 - 13.9 14.2 14.7 - 14.7 15.0 15.4 -
HI PR 241 260 274 - 271 291 308 - 308 331 350 - 351 377 399 - 395 425 448 - 436 469 495 -
LO PR 108 115 125 - 114 121 132 - 118 126 137 - 124 132 144 - 130 139 151 - 135 143 156 -
MBh 33.5 34.7 38.0 - 32.7 33.9 37.1 - 31.9 33.1 36.3 - 31.2 32.3 35.4 - 29.6 30.7 33.6 - 27.4 28.4 31.1 -
S/T 0.71 0.59 0.41 - 0.73 0.61 0.43 - 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.81 0.68 0.47 -
Delta T 18 16 12 - 18 16 12 - 18 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
70 1200 KW 2.52 2.57 2.64 - 2.70 2.76 2.84 - 2.86 2.93 3.02 - 3.01 3.07 3.17 - 3.13 3.20 3.30 - 3.24 3.31 3.42 -
AMPS 10.8 11.0 11.3 - 11.6 11.8 12.1 - 12.4 12.6 13.0 - 13.1 13.4 13.8 - 13.8 14.1 14.5 - 14.5 14.9 15.3 -
HI PR 239 257 271 - 268 288 305 - 305 328 346 - 347 374 395 - 391 420 444 - 432 464 490 -
LO PR 107 114 124 - 113 120 131 - 117 125 136 - 123 131 143 - 129 137 150 - 133 142 155 -
MBh 30.9 32.0 35.1 - 30.2 31.3 34.3 - 29.5 30.5 33.5 - 28.8 29.8 32.7 - 27.3 28.3 31.0 - 25.3 26.2 28.7 -
S/T 0.68 0.57 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.78 0.65 0.45 - 0.78 0.66 0.45 -
Delta T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -
1050 KW 2.46 2.51 2.58 - 2.64 2.69 2.77 - 2.80 2.86 2.94 - 2.94 3.00 3.09 - 3.06 3.12 3.22 - 3.16 3.23 3.33 -
AMPS 10.6 10.8 11.1 - 11.3 11.5 11.8 - 12.1 12.3 12.7 - 12.8 13.1 13.4 - 13.5 13.8 14.2 - 14.2 14.5 14.9 -
HI PR 232 249 263 - 260 280 295 - 296 318 336 - 337 362 383 - 379 408 431 - 419 451 476 -
LO PR 103 110 120 - 109 116 127 - 114 121 132 - 119 127 139 - 125 133 145 - 129 138 150 -
MBh 35.1 36.1 39.1 42.0 34.3 35.3 38.2 41.0 33.4 34.4 37.3 40.0 32.6
33.6
36.4 39.0 31.0 31.9 34.5 37.1 28.7 29.6 32.0 34.3
S/T 0.84 0.76 0.57 0.37 0.88 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93
0.83
0.63 0.40 0.96 0.86 0.65 0.42 0.97 0.87 0.66 0.42
Delta T20191511201915112019151121
19
16 11 20 19 15 11 19 17 14 10
1350 KW 2.55 2.61 2.69 2.77 2.74 2.80 2.89 2.98 2.91 2.97 3.07 3.16 3.06
3.12
3.22 3.33 3.18 3.25 3.36 3.47 3.29 3.36 3.47 3.59
AMPS 11.0 11.2 11.5 11.9 11.7 12.0 12.3 12.7 12.6 12.8 13.2 13.6 13.3
13.6
14.0 14.4 14.1 14.4 14.8 15.3 14.8 15.1 15.5 16.1
HI PR 244 262 277 289 274 294 311 324 311 335 353 369 354
381
403 420 399 429 453 472 440 474 500 522
LO PR 109 116 126 135 115 122 134 142 120 127 139 148 126
134
146 155 132 140 153 163 136 145 158 168
MBh 34.1 35.1 38.0 40.7 33.3 34.2 37.1 39.8 32.5 33.4 36.2 38.8 31.7
32.6
35.3 37.9 30.1 31.0 33.5 36.0 27.9 28.7 31.1 33.3
S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.88
0.79
0.60 0.38 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40
Delta T21191611212016112120161121
20
16 11 21 19 16 11 20 18 15 10
75 1200 KW 2.53 2.59 2.67 2.75 2.72 2.78 2.87 2.96 2.89 2.95 3.04 3.14 3.03
3.10
3.20 3.30 3.16 3.23 3.33 3.44 3.27 3.34 3.44 3.56
AMPS 10.9 11.1 11.4 11.8 11.6 11.9 12.2 12.6 12.5 12.7 13.1 13.5 13.2
13.5
13.9 14.3 13.9 14.2 14.7 15.1 14.7 15.0 15.4 15.9
HI PR 241 260 274 286 271 291 308 321 308 331 350 365 351
377
399 416 395 425 448 468 436 469 495 517
LO PR 108 115 125 133 114 121 132 141 118 126 137 146 124
132
144 154 130 139 151 161 135 143 157 167
MBh 31.4 32.4 35.0 37.6 30.7 31.6 34.2 36.7 30.0 30.9 33.4 35.8 29.2
30.1
32.6 35.0 27.8 28.6 31.0 33.2 25.7 26.5 28.7 30.8
S/T 0.78 0.69 0.53 0.34 0.81 0.72 0.55 0.35 0.83 0.74 0.56 0.36 0.85
0.76
0.58 0.37 0.88 0.79 0.60 0.39 0.89 0.80 0.60 0.39
Delta T21201611222016112220161122
20
16 11 22 20 16 11 20 19 15 10
1050 KW 2.48 2.53 2.60 2.68 2.66 2.71 2.80 2.89 2.82 2.88 2.97 3.06 2.96
3.02
3.12 3.22 3.08 3.15 3.25 3.35 3.19 3.25 3.36 3.47
AMPS 10.7 10.9 11.2 11.5 11.4 11.6 11.9 12.3 12.2 12.4 12.8 13.2 12.9
13.2
13.5 14.0 13.6 13.9 14.3 14.8 14.3 14.6 15.0 15.5
HI PR 234 252 266 277 263 283 299 311 299 321 339 354 340
366
387 403 383 412 435 454 423 455 481 501
LO PR 105 111 121 129 110 118 128 137 115 122 133 142 121
128
140 149 126 134 147 156 131 139 152 162
* IDB: Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction access fittings.