22
COOLING PERFORMANCE DATA GPC1348H41BA
MODEL: GPC1348H41**
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 12±3 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 8±3 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 44.6 46.2 50.6 - 43.5 45.1 49.5 - 42.5 44.1 48.3 - 41.5 43.0 47.1 - 39.4 40.8 44.7 - 36.5 37.8 41.4 -
S/T 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.87 0.73 0.50 - 0.88 0.73 0.51 -
Delta T171511 - 181512 - 181512 - 18 15 12 - 181512 - 161411 -
1800 KW 3.20 3.27 3.36 - 3.43 3.49 3.60 - 3.62 3.70 3.81 - 3.80 3.87 3.99 - 3.95 4.03 4.15 - 4.07 4.16 4.29 -
AMPS 13.9 14.2 14.5 - 14.8 15.1 15.5 - 15.9 16.2 16.6 - 16.8 17.1 17.6 - 17.7 18.0 18.5 - 18.5 18.9 19.5 -
HI PR 234 252 266 - 262 282 298 - 298 321 339 - 340 366 386 - 382 411 434 - 422 454 480 -
LO PR 112 119 130 - 118 125 137 - 123 130 142 - 129 137 149 - 135 143 157 - 139 148 162 -
MBh 43.3 44.9 49.2 - 42.3 43.8 48.0 - 41.3 42.8 46.9 - 40.3 41.7 45.7 - 38.3 39.6 43.4 - 35.4 36.7 40.2 -
S/T 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.84 0.70 0.49 -
Delta T181612 - 181612 - 181612 - 19 16 12 - 181612 - 171511 -
70 1600 KW 3.18 3.24 3.34 - 3.40 3.47 3.57 - 3.60 3.67 3.78 - 3.77 3.85 3.96 - 3.92 4.00 4.12 - 4.04 4.12 4.25 -
AMPS 13.8 14.1 14.4 - 14.7 15.0 15.4 - 15.7 16.0 16.5 - 16.6 17.0 17.4 - 17.5 17.9 18.4 - 18.4 18.8 19.3 -
HI PR 231 249 263 - 260 279 295 - 295 318 336 - 336 362 382 - 378 407 430 - 418 450 475 -
LO PR 110 118 128 - 117 124 136 - 121 129 141 - 127 136 148 - 134 142 155 - 138 147 160 -
MBh 40.0 41.4 45.4 - 39.0 40.4 44.3 - 38.1 39.5 43.3 - 37.2 38.5 42.2 - 35.3 36.6 40.1 - 32.7 33.9 37.1 -
S/T 0.70 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.77 0.65 0.45 - 0.80 0.67 0.46 - 0.81 0.68 0.47 -
Delta T181612 - 191612 - 191612 - 19 16 12 - 191612 - 171511 -
1400 KW 3.11 3.17 3.26 - 3.33 3.39 3.49 - 3.52 3.59 3.69 - 3.68 3.76 3.87 - 3.82 3.90 4.02 - 3.95 4.03 4.15 -
AMPS 13.5 13.8 14.1 - 14.4 14.7 15.0 - 15.4 15.7 16.1 - 16.2 16.6 17.0 - 17.1 17.5 18.0 - 18.0 18.3 18.9 -
HI PR 224 242 255 - 252 271 286 - 286 308 326 - 326 351 371 - 367 395 417 - 406 436 461 -
LO PR 107 114 124 - 113 120 131 - 118 125 137 - 124 131 144 - 130 138 150 - 134 143 156 -
MBh 45.3 46.7 50.5 54.2 44.3 45.6 49.4 53.0 43.2 44.5 48.2 51.7 42.2
43.4
47.0 50.4 40.1 41.3 44.7 47.9 37.1 38.2 41.4 44.4
S/T 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.93 0.83 0.63 0.40 0.96
0.85
0.65 0.42 0.99 0.89 0.67 0.43 1.00 0.89 0.68 0.44
Delta T20191511201915112019151121
19
16 11 20 19 15 11 19 17 14 10
1800 KW 3.23 3.29 3.38 3.48 3.45 3.52 3.62 3.73 3.65 3.73 3.84 3.95 3.83
3.91
4.02 4.15 3.98 4.06 4.18 4.31 4.10 4.19 4.32 4.46
AMPS 14.0 14.3 14.7 15.1 14.9 15.2 15.6 16.1 16.0 16.3 16.7 17.3 16.9
17.2
17.7 18.3 17.8 18.2 18.7 19.3 18.7 19.1 19.6 20.3
HI PR 236 254 268 280 265 285 301 314 301 324 342 357 343
369
390 407 386 415 439 458 427 459 485 506
LO PR 113 120 131 139 119 127 138 147 124 132 144 153 130
138
151 161 136 145 158 169 141 150 164 174
MBh 44.0 45.3 49.1 52.7 43.0 44.3 47.9 51.4 42.0 43.2 46.8 50.2 41.0
42.2
45.6 49.0 38.9 40.1 43.4 46.5 36.0 37.1 40.2 43.1
S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.60 0.38 0.91
0.82
0.62 0.40 0.95 0.85 0.64 0.41 0.95 0.85 0.65 0.42
Delta T21191611212016112120161121
20
16 11 21 19 16 11 20 18 15 10
75 1600 KW 3.21 3.27 3.36 3.46 3.43 3.50 3.60 3.71 3.62 3.70 3.81 3.92 3.80
3.88
3.99 4.12 3.95 4.03 4.15 4.28 4.07 4.16 4.29 4.42
AMPS 13.9 14.2 14.5 15.0 14.8 15.1 15.5 16.0 15.9 16.2 16.6 17.1 16.8
17.1
17.6 18.1 17.7 18.0 18.5 19.1 18.5 18.9 19.5 20.1
HI PR 234 252 266 277 262 282 298 311 298 321 339 354 340
366
386 403 382 411 434 453 422 454 480 501
LO PR 112 119 130 138 118 125 137 146 123 130 142 152 129
137
149 159 135 144 157 167 140 148 162 173
MBh 40.6 41.8 45.3 48.6 39.7 40.9 44.2 47.5 38.7 39.9 43.2 46.3 37.8
38.9
42.1 45.2 35.9 37.0 40.0 42.9 33.3 34.2 37.1 39.8
S/T 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88
0.79
0.59 0.38 0.91 0.82 0.62 0.40 0.92 0.82 0.62 0.40
Delta T21201611222016112220161122
20
16 11 22 20 16 11 20 19 15 10
1400 KW 3.14 3.20 3.29 3.38 3.35 3.42 3.52 3.62 3.54 3.61 3.72 3.83 3.71
3.79
3.90 4.02 3.85 3.93 4.05 4.18 3.98 4.06 4.18 4.32
AMPS 13.6 13.9 14.2 14.7 14.5 14.8 15.2 15.6 15.5 15.8 16.2 16.7 16.4
16.7
17.2 17.7 17.2 17.6 18.1 18.7 18.1 18.5 19.0 19.6
HI PR 227 244 258 269 254 274 289 302 289 311 329 343 330
355
375 391 371 399 421 439 410 441 466 486
LO PR 108 115 126 134 114 122 133 141 119 126 138 147 125
133
145 154 131 139 152 162 135 144 157 167
* IDB: Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction access fittings.