Goodmans GPC1324H41A Air Conditioner User Manual


 
14
COOLING PERFORMANCE DATA GPC1324H41AA
MODEL: GPC1324H41A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 12±3 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 8±3 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 23.5 24.4 26.7 - 23.0 23.8 26.1 - 22.4 23.2 25.5 - 21.9 22.7 24.8 - 20.8 21.5 23.6 - 19.3 20.0 21.9 -
S/T 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.83 0.70 0.48 - 0.86 0.72 0.50 - 0.89 0.74 0.52 - 0.90 0.75 0.52 -
Delta T171511 - 171511 - 181512 - 18 15 12 - 171511 - 161411 -
980 KW 1.71 1.74 1.79 - 1.83 1.87 1.93 - 1.94 1.98 2.05 - 2.04 2.08 2.15 - 2.12 2.17 2.24 - 2.20 2.24 2.32 -
AMPS 7.1 7.3 7.5 - 7.6 7.8 8.0 - 8.2 8.3 8.6 - 8.7 8.8 9.1 - 9.1 9.3 9.6 - 9.6 9.8 10.1 -
HI PR 222 239 252 - 249 268 283 - 283 305 322 - 323 347 367 - 363 391 413 - 401 432 456 -
LO PR 112 119 130 - 118 126 137 - 123 131 143 - 129 137 150 - 135 144 157 - 140 149 163 -
MBh 22.8 23.7 25.9 - 22.3 23.1 25.3 - 21.8 22.6 24.7 - 21.2 22.0 24.1 - 20.2 20.9 22.9 - 18.7 19.4 21.2 -
S/T 0.75 0.62 0.43 - 0.77 0.65 0.45 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.86 0.72 0.50 -
Delta T181612 - 181612 - 181612 - 18 16 12 - 181612 - 171511 -
70 875 KW 1.69 1.73 1.78 - 1.82 1.85 1.91 - 1.93 1.97 2.03 - 2.02 2.07 2.13 - 2.11 2.15 2.22 - 2.18 2.23 2.30 -
AMPS 7.1 7.2 7.4 - 7.6 7.7 7.9 - 8.1 8.3 8.5 - 8.6 8.8 9.0 - 9.1 9.3 9.5 - 9.5 9.8 10.0 -
HI PR 220 237 250 - 247 265 280 - 281 302 319 - 320 344 363 - 360 387 409 - 397 427 451 -
LO PR 111 118 129 - 117 125 136 - 122 130 141 - 128 136 149 - 134 143 156 - 139 148 161 -
MBh 21.7 22.5 24.6 - 21.2 22.0 24.1 - 20.7 21.4 23.5 - 20.2 20.9 22.9 - 19.2 19.9 21.8 - 17.8 18.4 20.2 -
S/T 0.72 0.60 0.41 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.45 - 0.81 0.68 0.47 - 0.82 0.69 0.48 -
Delta T191612 - 191612 - 191612 - 19 16 12 - 191612 - 171511 -
770 KW 1.67 1.70 1.75 - 1.79 1.83 1.88 - 1.90 1.94 2.00 - 1.99 2.03 2.10 - 2.07 2.12 2.19 - 2.14 2.19 2.26 -
AMPS 7.0 7.1 7.3 - 7.4 7.6 7.8 - 8.0 8.2 8.4 - 8.5 8.6 8.9 - 8.9 9.1 9.4 - 9.4 9.6 9.9 -
HI PR 215 232 245 - 242 260 275 - 275 296 312 - 313 337 356 - 352 379 400 - 389 419 442 -
LO PR 109 116 126 - 115 122 133 - 119 127 139 - 125 133 146 - 131 140 153 - 136 145 158 -
MBh 23.9 24.6 26.7 28.6 23.4 24.1 26.0 27.9 22.8 23.5 25.4 27.3 22.2
22.9
24.8 26.6 21.1 21.8 23.6 25.3 19.6 20.2 21.8 23.4
S/T 0.89 0.80 0.60 0.39 0.92 0.83 0.62 0.40 0.95 0.85 0.64 0.41 0.98
0.87
0.66 0.43 1.00 0.91 0.69 0.44 1.00 0.91 0.69 0.45
Delta T20181510201915112019151120
19
15 11 20 19 15 10 18 17 14 10
980 KW 1.72 1.75 1.81 1.86 1.85 1.88 1.94 2.00 1.96 2.00 2.06 2.13 2.06
2.10
2.17 2.24 2.14 2.19 2.26 2.33 2.21 2.26 2.34 2.41
AMPS 7.27.37.57.87.77.88.18.38.28.48.78.98.7
8.9
9.2 9.5 9.2 9.4 9.7 10.0 9.7 9.9 10.2 10.6
HI PR 224 241 255 266 252 271 286 298 286 308 325 339 326
351
371 386 367 395 417 435 405 436 461 480
LO PR 113 120 131 140 120 127 139 148 124 132 144 154 131
139
152 161 137 146 159 169 141 151 164 175
MBh 23.2 23.9 25.9 27.8 22.7 23.4 25.3 27.1 22.1 22.8 24.7 26.5 21.6
22.2
24.1 25.8 20.5 21.1 22.9 24.5 19.0 19.6 21.2 22.7
S/T 0.85 0.76 0.57 0.37 0.88 0.79 0.60 0.38 0.90 0.81 0.61 0.39 0.93
0.83
0.63 0.41 0.97 0.86 0.65 0.42 0.97 0.87 0.66 0.42
Delta T21191611211916112119161121
19
16 11 21 19 16 11 19 18 15 10
75 875 KW 1.71 1.74 1.79 1.85 1.83 1.87 1.93 1.99 1.94 1.98 2.05 2.11 2.04
2.08
2.15 2.22 2.12 2.17 2.24 2.31 2.20 2.24 2.32 2.39
AMPS 7.17.37.57.77.67.88.08.28.28.38.68.98.7
8.8
9.1 9.4 9.1 9.3 9.6 9.9 9.6 9.8 10.1 10.5
HI PR 222 239 252 263 249 268 283 295 283 305 322 336 323
347
367 383 363 391 413 430 401 432 456 476
LO PR 112 119 130 139 118 126 137 146 123 131 143 152 129
137
150 160 135 144 157 168 140 149 163 173
MBh 22.1 22.7 24.6 26.4 21.5 22.2 24.0 25.8 21.0 21.7 23.4 25.2 20.5
21.1
22.9 24.5 19.5 20.1 21.7 23.3 18.1 18.6 20.1 21.6
S/T 0.81 0.73 0.55 0.35 0.84 0.75 0.57 0.37 0.86 0.77 0.59 0.38 0.89
0.80
0.60 0.39 0.93 0.83 0.63 0.40 0.93 0.84 0.63 0.41
Delta T21201611222016112220161122
20
16 11 22 20 16 11 20 19 15 10
770 KW 1.68 1.71 1.77 1.82 1.80 1.84 1.90 1.96 1.91 1.95 2.01 2.08 2.01
2.05
2.12 2.18 2.09 2.14 2.20 2.28 2.16 2.21 2.28 2.35
AMPS 7.07.27.47.67.57.77.98.18.08.28.58.78.5
8.7
9.0 9.3 9.0 9.2 9.5 9.8 9.5 9.7 10.0 10.3
HI PR 218 234 247 258 244 263 278 289 278 299 316 329 316
340
360 375 356 383 404 422 393 423 447 466
LO PR 110 117 128 136 116 123 135 143 121 128 140 149 127
135
147 157 133 141 154 164 137 146 159 170
* IDB: Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions