Goodmans GPC1324H41A Air Conditioner User Manual


 
19
COOLING PERFORMANCE DATA GPC1336H41AA
MODEL: GPC1336H41A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 12±3 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 8±3 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 35.7 36.5 39.0 41.7 34.9 35.6 38.1 40.7 34.0 34.8 37.2 39.7 33.2 33.9 36.3 38.8 31.5 32.2 34.4 36.8 29.2 29.9 31.9 34.1
S/T 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.92 0.75 0.56 1.00 0.95 0.78 0.58 1.00 1.00 0.81 0.60 1.00 1.00 0.81 0.61
Delta T23221915232219152322191523 22 19 152122191520201814
1350 KW 2.57 2.63 2.71 2.79 2.77 2.82 2.91 3.00 2.93 3.00 3.09 3.19 3.08 3.15 3.25 3.36 3.21 3.28 3.39 3.50 3.32 3.39 3.50 3.62
AMPS 11.1 11.3 11.6 12.0 11.8 12.1 12.4 12.8 12.7 12.9 13.3 13.7 13.4 13.7 14.1 14.6 14.2 14.5 14.9 15.4 14.9 15.2 15.7 16.2
HI PR 246 265 280 292 276 297 314 327 314 338 357 372 358 385 407 424 403 433 458 477 445 479 505 527
LO PR 110 117 128 136 116 124 135 144 121 128 140 149 127 135 147 157 133 141 154 164 137 146 160 170
MBh 34.7 35.4 37.8 40.5 33.9 34.6 37.0 39.5 33.0 33.8 36.1 38.6 32.2 32.9
35.2
37.6 30.6 31.3 33.4 35.7 28.4 29.0 31.0 33.1
S/T 0.88 0.83 0.67 0.50 0.92 0.86 0.70 0.52 0.94 0.88 0.72 0.54 0.97 0.91
0.74
0.55 1.00 0.94 0.77 0.57 1.00 0.95 0.77 0.58
Delta T23222016242320162423201624 23
20
16 23 23 20 16 22 21 18 15
80 1200 KW 2.55 2.61 2.69 2.77 2.74 2.80 2.89 2.98 2.91 2.97 3.07 3.17 3.06 3.12
3.22
3.33 3.18 3.25 3.36 3.47 3.29 3.36 3.47 3.59
AMPS 11.0 11.2 11.5 11.9 11.7 12.0 12.3 12.7 12.6 12.8 13.2 13.6 13.3 13.6
14.0
14.4 14.1 14.4 14.8 15.3 14.8 15.1 15.5 16.1
HI PR 244 262 277 289 274 294 311 324 311 335 354 369 354 381
403
420 399 429 453 472 440 474 500 522
LO PR 109 116 126 135 115 122 134 142 120 127 139 148 126 134
146
155 132 140 153 163 136 145 158 168
MBh 32.0 32.7 34.9 37.3 31.2 31.9 34.1 36.5 30.5 31.2 33.3 35.6 29.8 30.4 32.5 34.7 28.3 28.9 30.9 33.0 26.2 26.8 28.6 30.6
S/T 0.85 0.80 0.65 0.49 0.88 0.83 0.67 0.50 0.91 0.85 0.69 0.52 0.93 0.88 0.71 0.53 0.97 0.91 0.74 0.55 0.98 0.92 0.75 0.56
Delta T24232016242320162423201624 23 20 162423201622211915
1050 KW 2.50 2.55 2.62 2.70 2.68 2.73 2.82 2.91 2.84 2.90 2.99 3.09 2.98 3.05 3.15 3.25 3.11 3.17 3.28 3.38 3.21 3.28 3.39 3.50
AMPS 10.7 11.0 11.3 11.6 11.5 11.7 12.0 12.4 12.3 12.5 12.9 13.3 13.0 13.3 13.7 14.1 13.7 14.0 14.4 14.9 14.4 14.7 15.2 15.7
HI PR 236 254 269 280 265 286 302 314 302 325 343 358 344 370 391 407 387 416 439 458 427 460 485 506
LO PR 106 112 123 131 112 119 130 138 116 123 135 143 122 130 141 151 128 136 148 158 132 140 153 163
MBh 36.3 37.0 38.8 41.4 35.5 36.2 37.9 40.4 34.6 35.3 37.0 39.4 33.8 34.4 36.1 38.5 32.1 32.7 34.3 36.6 29.7 30.3 31.7 33.9
S/T 0.97 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.93 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.97 0.79
Delta T24242219242423202424232023 23 23 202222221920212118
1350 KW 2.59 2.65 2.73 2.81 2.79 2.85 2.93 3.03 2.96 3.02 3.12 3.22 3.11 3.18 3.28 3.38 3.24 3.31 3.41 3.53 3.35 3.42 3.53 3.65
AMPS 11.2 11.4 11.7 12.1 11.9 12.2 12.5 12.9 12.8 13.0 13.4 13.9 13.5 13.8 14.2 14.7 14.3 14.6 15.0 15.5 15.0 15.3 15.8 16.3
HI PR 249 268 283 295 279 300 317 331 317 342 361 376 361 389 411 428 407 438 462 482 449 483 511 533
LO PR 111 118 129 137 117 125 136 145 122 130 142 151 128 136 149 158 134 143 156 166 139 148 161 172
MBh 35.3 35.9 37.7 40.2 34.4 35.1 36.8 39.2 33.6 34.3 35.9 38.3 32.8 33.4 35.0 37.4 31.2 31.8 33.3 35.5 28.9 29.4 30.8 32.9
S/T 0.93 0.89 0.81 0.65 0.96 0.93 0.84 0.68 0.98 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.93 0.75
Delta T25252320252524202525242025 25 24 212424232022232219
85 1200 KW 2.57 2.63 2.71 2.79 2.77 2.82 2.91 3.00 2.93 3.00 3.09 3.19 3.08 3.15 3.25 3.36 3.21 3.28 3.39 3.50 3.32 3.39 3.50 3.62
AMPS 11.1 11.3 11.6 12.0 11.8 12.1 12.4 12.8 12.7 12.9 13.3 13.7 13.4 13.7 14.1 14.6 14.2 14.5 14.9 15.4 14.9 15.2 15.7 16.2
HI PR 246 265 280 292 276 297 314 327 314 338 357 372 358 385 407 424 403 433 458 477 445 479 505 527
LO PR 110 117 128 136 116 124 135 144 121 128 140 149 127 135 147 157 133 141 154 164 137 146 160 170
MBh 32.6 33.2 34.8 37.1 31.8 32.4 33.9 36.2 31.0 31.6 33.1 35.4 30.3 30.9 32.3 34.5 28.8 29.3 30.7 32.8 26.6 27.2 28.4 30.3
S/T 0.89 0.86 0.78 0.63 0.93 0.89 0.81 0.65 0.95 0.92 0.83 0.67 0.98 0.95 0.85 0.69 1.00 0.98 0.89 0.72 1.00 0.99 0.89 0.72
Delta T25252420262524212625242126 26 24 212525242123242219
1050 KW 2.51 2.57 2.64 2.73 2.70 2.76 2.84 2.93 2.86 2.92 3.02 3.11 3.01 3.07 3.17 3.27 3.13 3.20 3.30 3.41 3.24 3.31 3.42 3.53
AMPS 10.8 11.0 11.3 11.7 11.5 11.8 12.1 12.5 12.4 12.6 13.0 13.4 13.1 13.4 13.8 14.2 13.8 14.1 14.5 15.0 14.5 14.8 15.3 15.8
HI PR 239 257 271 283 268 288 305 318 305 328 346 361 347 374 394 411 391 420 444 463 431 464 490 511
LO PR 107 113 124 132 113 120 131 139 117 125 136 145 123 131 143 152 129 137 150 159 133 142 155 165
* NOTE: Shaded areas is AHRI Rating Conditions IDB: Entering Indoor Dry Bulb Temperature KW = Total system power
High and low pressures are measured at the liquid and suction access fittings. AMPS: Unit amps (comp.+ evaporator + condenser fan motors)