16
COOLING PERFORMANCE DATA GPC1330H41AA
MODEL: GPC1330H41A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 12±3 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 8±3 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 28.2 29.3 32.0 - 27.6 28.6 31.3 - 26.9 27.9 30.6 - 26.3 27.2 29.8 - 24.9 25.8 28.3 - 23.1 23.9 26.2 -
S/T 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.84 0.70 0.49 - 0.87 0.72 0.50 - 0.90 0.75 0.52 - 0.91 0.76 0.53 -
Delta T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 17 15 11 - 16 14 11 -
1180 KW 2.07 2.11 2.17 - 2.22 2.26 2.33 - 2.35 2.40 2.47 - 2.46 2.52 2.59 - 2.56 2.62 2.70 - 2.65 2.70 2.79 -
AMPS 8.8 9.0 9.2 - 9.4 9.6 9.8 - 10.0 10.2 10.5 - 10.6 10.8 11.1 - 11.2 11.4 11.8 - 11.8 12.0 12.4 -
HI PR 232 249 263 - 260 280 295 - 296 318 336 - 337 362 382 - 379 407 430 - 418 450 475 -
LO PR 111 118 129 - 118 125 137 - 122 130 142 - 128 137 149 - 135 143 156 - 139 148 162 -
MBh 27.4 28.4 31.1 - 26.8 27.7 30.4 - 26.1 27.1 29.7 - 25.5 26.4 28.9 - 24.2 25.1 27.5 - 22.4 23.2 25.5 -
S/T 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.87 0.72 0.50 -
Delta T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
70 1050 KW 2.05 2.09 2.16 - 2.20 2.25 2.31 - 2.33 2.38 2.45 - 2.45 2.50 2.57 - 2.54 2.60 2.68 - 2.63 2.68 2.77 -
AMPS 8.7 8.9 9.1 - 9.3 9.5 9.8 - 10.0 10.2 10.5 - 10.5 10.8 11.1 - 11.1 11.3 11.7 - 11.7 11.9 12.3 -
HI PR 229 247 261 - 257 277 292 - 293 315 332 - 333 359 379 - 375 403 426 - 414 446 471 -
LO PR 110 117 128 - 116 124 135 - 121 129 141 - 127 135 148 - 133 142 155 - 138 147 160 -
MBh 25.3 26.2 28.7 - 24.7 25.6 28.1 - 24.1 25.0 27.4 - 23.5 24.4 26.7 - 22.3 23.2 25.4 - 20.7 21.5 23.5 -
S/T 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.77 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.83 0.70 0.48 -
Delta T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
920 KW 2.01 2.05 2.11 - 2.15 2.19 2.26 - 2.28 2.32 2.39 - 2.39 2.44 2.51 - 2.48 2.53 2.61 - 2.56 2.62 2.70 -
AMPS 8.5 8.7 8.9 - 9.1 9.3 9.5 - 9.7 9.9 10.2 - 10.3 10.5 10.8 - 10.9 11.1 11.4 - 11.4 11.6 12.0 -
HI PR 222 239 253 - 250 269 284 - 284 305 322 - 323 348 367 - 364 391 413 - 402 432 457 -
LO PR 107 114 124 - 113 120 131 - 117 125 136 - 123 131 143 - 129 137 150 - 134 142 155 -
MBh 28.7 29.5 32.0 34.3 28.0 28.9 31.2 33.5 27.4 28.2 30.5 32.7 26.7
27.5
29.8 31.9 25.4 26.1 28.3 30.3 23.5 24.2 26.2 28.1
S/T 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.41 0.95 0.85 0.65 0.42 0.99
0.88
0.67 0.43 1.00 0.91 0.69 0.45 1.00 0.92 0.70 0.45
Delta T20191510201915112019151120
19
15 11 20 19 15 11 18 17 14 10
1180 KW 2.08 2.13 2.19 2.25 2.23 2.28 2.35 2.42 2.37 2.42 2.49 2.57 2.48
2.54
2.62 2.70 2.58 2.64 2.72 2.81 2.67 2.73 2.81 2.91
AMPS 8.9 9.0 9.3 9.6 9.4 9.6 9.9 10.2 10.1 10.3 10.6 11.0 10.7
10.9
11.2 11.6 11.3 11.5 11.9 12.2 11.9 12.1 12.5 12.9
HI PR 234 252 266 277 262 282 298 311 299 321 339 354 340
366
386 403 382 412 435 453 423 455 480 501
LO PR 112 120 131 139 119 126 138 147 123 131 143 153 130
138
151 160 136 145 158 168 141 150 163 174
MBh 27.9 28.7 31.1 33.3 27.2 28.0 30.3 32.6 26.6 27.4 29.6 31.8 25.9
26.7
28.9 31.0 24.6 25.4 27.4 29.5 22.8 23.5 25.4 27.3
S/T 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.91 0.81 0.62 0.40 0.94
0.84
0.64 0.41 0.98 0.87 0.66 0.42 0.98 0.88 0.67 0.43
Delta T21191611211916112120161121
20
16 11 21 19 16 11 20 18 15 10
75 1050 KW 2.07 2.11 2.17 2.24 2.22 2.26 2.33 2.40 2.35 2.40 2.47 2.55 2.47
2.52
2.60 2.68 2.56 2.62 2.70 2.79 2.65 2.71 2.79 2.88
AMPS 8.8 9.0 9.2 9.5 9.4 9.6 9.8 10.1 10.0 10.3 10.5 10.9 10.6
10.8
11.2 11.5 11.2 11.4 11.8 12.2 11.8 12.0 12.4 12.8
HI PR 232 249 263 275 260 280 295 308 296 318 336 350 337
362
383 399 379 408 430 449 418 450 475 496
LO PR 111 118 129 138 118 125 137 145 122 130 142 151 128
137
149 159 135 143 156 166 139 148 162 172
MBh 25.7 26.5 28.7 30.8 25.1 25.9 28.0 30.0 24.5 25.2 27.3 29.3 23.9
24.6
26.7 28.6 22.7 23.4 25.3 27.2 21.1 21.7 23.5 25.2
S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.59 0.38 0.91
0.81
0.61 0.39 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41
Delta T21201611212016112220161122
20
16 11 21 20 16 11 20 18 15 10
920 KW 2.02 2.06 2.12 2.19 2.17 2.21 2.28 2.35 2.29 2.34 2.41 2.49 2.41
2.46
2.53 2.61 2.50 2.56 2.64 2.72 2.59 2.64 2.72 2.81
AMPS 8.6 8.8 9.0 9.3 9.2 9.3 9.6 9.9 9.8 10.0 10.3 10.6 10.4
10.6
10.9 11.2 10.9 11.2 11.5 11.9 11.5 11.7 12.1 12.5
HI PR 225 242 255 266 252 271 286 299 287 309 326 340 327
351
371 387 367 395 417 435 406 437 461 481
LO PR 108 115 125 134 114 121 132 141 119 126 138 147 125
132
145 154 130 139 152 161 135 144 157 167
* IDB: Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction access fittings.