FIG. 6-6 2 x 4 under center of door opening.
CONTACT REVERSE TEST
The force adjustments and limit switch settings
MUST BE COMPLETED before testing.
1. Testing.
Open garage door using Wall Button.
– Place a 2" x 4" board (laid flat) under center
of garage door opening (Fig. 6-6).
Close door using Wall Button.
When door contacts board, it must stop and
reverse (within 2 seconds) to open position.
2. Adjustment.
If the door does not properly reverse.
– Check to see if door has "close" limit
programmed. It should not have reached its
"close" limit before hitting board.
– If the door STOPS but does not reverse,
decrease "CLOSE FORCE" control
setting slightly (turn it counter-clockwise).
Test again. Repeat as necessary until door
reverses upon contacting board.
CLOSE
1. Press and hold both of the "SET" buttons
( & ) together until the green indicator
light blinks (about 5 seconds).
2. All close and open travel limit settings are
erased. Then follow the steps above to
reprogram close and open travel limits.
NOTE: The opener will not close the door
automatically unless the Safe-T-Beam
®
System is
installed.
SET
SET
1. By turning the Down Force Control clockwise,
the DOWN force can be increased. By turning
the Down Force Control counter-clockwise,
the DOWN force can be decreased. Set the
DOWN force level at the minimum force required
to close door without reversing.
2. Once the desired level is selected, this stores the
maximum force level for the DOWN direction in memory.
3. By turning the Up Force Control clockwise, the
UP force can be increased. By turning the Up Force
Control counter-clockwise, the UP force can be
decreased. Set the UP force level at the minimum
force required to open door without stopping.
4. Once the desired level is selected, this stores
the maximum force level for the UP direction
in memory.
OPEN
CLOSE
OPEN
CLOSE
UP/DOWN FORCE
ERASE - OPEN/CLOSE TRAVEL LIMIT
OPEN
FORCE
CLOSE
Down Force
Control
Adjustment
Up Force
Control
Adjustment
ROTATE
CLOCKWISE
ROTATE
COUNTER-CLOCKWISE
FIG. 6-5 Force Control Adjustment.