GE RAK147P1. RAL163P1 Thermostat User Manual


 
THERMOSTAT COVERED RAK163P1, RAK147P1
Power Requirements 18–30 VAC or VDC electronic thermostat for 5-wire
1H/1C systems (RAK163P1) and 6-wire 2H/1C systems (RAK147P1)
Temperature Measurement Range 50 to 99°F with 1°F display resolution
(10 to 37°C with 1°C display resolution)
Temperature Control Range 60 to 90°F with 1°F display resolution
(15 to 32°C with 1°C display resolution)
Storage Temperature Range -4 to 131°F (-20 to 50°C)
Time Display Format 12 hour with AM/PM
Program 5+2 and 7-day program with 4 time periods per day
10 Minute resolution for both heating and cooling programs
Independent heating and cooling programs
Auto Changeover Feature
Temperature Override Temporary program temperature override
Permanent program temperature override with
HOLD
feature
Recommended Wire Size 24–18 Gauge
Safety Circuit 1) Auto cut-off in heat mode if room temperature > 90°F
2) Auto cut-off in cool mode if room temperature < 60°F
Memory Backup Lithium Battery CR2032
Battery life > 10 years
Others EL type LCD backlight
Dimensions 4x 4-5/8x 1-5/16(101.6 x 117.5 x 33.3 mm)
Shipping Weight Approximately 0.5 lb. (0.231 kg)
14
Installation Instructions
SPECIFICATIONS