Friedrich PTAC - R410A Air Conditioner User Manual


 
48
Resistance Table for Frost Protection Indoor and Outdoor Temperature Sensors
Temp.
˄F˅
Resistance
˄kȍ˅
Temp.
˄F˅
Resistance
˄kȍ˅
Temp.
˄F˅
Resistance
˄kȍ˅
Temp.
˄F˅
Resistance
˄kȍ˅
-19 181.400
20 25.010
59 5.130
98 1.427
-18 171.400
21 23.900
60 4.948
99 1.386
-17 162.100
22 22.850
61 4.773
100 1.346
-16 153.300
23 21.850
62 4.605
101 1.307
-15 145.000
24 20.900
63 4.443
102 1.269
-14 137.200
25 20.000
64 4.289
103 1.233
-13 129.900
26 19.140
65 4.140
104 1.198
-12 123.000
27 18.130
66 3.998
105 1.164
-11 116.500
28 17.550
67 3.861
106 1.131
-10 110.300
29 16.800
68 3.729
107 1.099
-9 104.600
30 16.100
69 3.603
108 1.069
-8 99.130
31 15.430
70 3.481
109 1.039
-7 94.000
32 14.790
71 3.364
110 1.010
-6 89.170
33 14.180
72 3.252
111 0.983
-5 84.610
34 13.590
73 3.144
112 0.956
-4 80.310
35 13.040
74 3.040
113 0.930
-3 76.240
36 12.510
75 2.940
114 0.904
-2 72.410
37 12.000
76 2.844
115 0.880
-1 68.790
38 11.520
77 2.752
116 0.856
0 65.370
39 11.060
78 2.663
117 0.833
1 62.130
40 10.620
79 2.577
118 0.811
2 59.080
41 10.200
80 2.495
119 0.770
3 56.190
42 9.803
81 2.415
120 0.769
4 53.460
43 9.420
82 2.339
121 0.746
5 50.870
44 9.054
83 2.265
122 0.729
6 48.420
45 8.705
84 2.194
123 0.710
7 46.110
46 8.370
85 2.125
124 0.692
8 43.920
47 8.051
86 2.059
125 0.674
9 41.840
48 7.745
87 1.996
126 0.658
10 39.870
49 7.453
88 1.934
127 0.640
11 38.010
50 7.173
89 1.875
128 0.623
12 36.240
51 6.905
90 1.818
129 0.607
13 34.570
52 6.648
91 1.736
130 0.592
14 32.980
53 6.403
92 1.710
131 0.577
15 31.470
54 6.167
93 1.658
132 0.563
16 30.040
55 5.942
94 1.609
133 0.549
17 28.680
56 5.726
95 1.561
134 0.535
18 27.390
57 5.519
96 1.515
135 0.521
19 26.170
58 5.320
97 1.470
136 0.509