TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES (
59 thru
68, *70 thru
76, and
89):
For 3+1 or 4+1 Standard Format: Enter a code in the
first
box:
1–9, #+10 for 0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F.
A 0 (
not
#+10) in the
first
box disables a report. A 0 (
not
#+10) in the
second
box results in advance to the next field.
For Expanded or 4+2 Format: Enter codes in
both
boxes (1st and 2nd digits) for 1–9, 0, or B–F, as described above.
A 0 (
not
#+10) in the
second
box will eliminate the expanded message for that report. A 0 (
not
#+10) in
both
boxes will disable
the report.
For Ademco Contact ID® Reporting: Enter any digit (other than 0) in the
first
box, to enable zone to report (entries in the
second
boxes are ignored).A 0 (
not
#+10) in the
first
box disables the report.
UL: Report codes are required in fields *61, *65, *71, *72, for UL Commercial Burglar Alarm installations.
Report codes are required in fields *60, *62, *63, *64, *70, *73, *74, *75, *76, for UL Commercial Burglar Alarm installations and required for
Residential Fire Alarm installations
SYSTEM STATUS REPORT CODES (
59–
68)
59
Exit Error Alarm Report Code
See above for entries.
SIA-Compliant Controls:
[1] Always enabled.
[0]
After arming the system, entry/exit and interior zones remaining open
after exit delay expires cause an alarm sound at the keypad and
external sounder (keypad also displays “EXIT ALARM”), and entry
delay begins. Disarming before the end of the entry delay stops the
alarm sounding and no message is sent to the central station. The
keypad will display “CA” (fixed-word) or “ALARM CANCELED” (alpha
display).
If the s
y
stem is not disarmed before entr
y
dela
y
expires, an “EXIT
ALARM” message (SIA-Compliant Controls: also zone alarm
messa
g
e) will be sent to the central station. The ke
y
pad will displa
y
“EA”
(fixed-word ) or “EXIT ALARM” (alpha displa
y
), and alarm soundin
g
continues until the system is disarmed (or timeout occurs).
An Exit Alarm condition will also result if a fault occurs in an exit or
interior zone within 2 minutes following the end of the exit delay, and an
“EXIT ALARM” message will be sent to the central station (except for
SIA-Compliant Controls, see field *69 Recent Closing report). With
Contact ID format, the message will contain the zone number
and error code 374 (“ALARM–EXIT ERROR”).
60
Trouble Report Code
See above for entries.
| [10]
Sent if a zone has a trouble condition.
See UL System Reporting Note above *59.
61
Bypass Report Code
See above for entries.
| [00]
Sent when a zone is manually bypassed.
See UL System Reporting Note above *59.
62
AC Loss Report Code
See above for entries.
| [10]
Timing of this report is random with up to a 4-hour delay. If AC restores
before the report goes out, there is no “AC LOSS” report.
See UL System Reporting Note above *59.
63
Low Bat Report Code
See above for entries.
| [10]
Sent when the system’s backup battery has a low-battery condition.
See UL System Reporting Note above *59
64
Test Report Code
See above for entries.
Periodic Test Report Scheduling
Commands:
installer code +[#] + [0] + 0 = report
every 24 hrs
installer code +[#] + [0] + 1 = report once
per week
installer code +[#] + [0] + 2 = report
every 28 days
| [00]
Sent periodically to test that the communicator and phone lines are
operational.
Frequency of report is set in Scheduling mode (event 11) or by the key
commands listed at left:
Each mode sets schedule 32 (FA168CPS) or schedule 08 (FA148CP)
to the stated repeat option; first test report sent 12 hours after
command.
See System Reporting UL Note above *59.
† NOTE: Make sure the Real-Time Clock is set to the proper time before
entering the test report schedule command to ensure that test reports are sent
when expected. (see Setting the Real-Time Clock section)
65
Open Report Code
See above for entries.
[0,0,0]
Part. 1 Part. 2 Common
Sent upon disarming the system in the selected partitions.
See UL System Reporting Note above *59.