– 27 –
“C”
01 Enter Zn No.
12
Zone Number
Press [
✱
] to continue.
(prompt appears if zone number was selected)
Enter the desired zone number associated with this output
number. At the ENTER EVENT prompt, enter the zone event
that will activate this output.
01 Enter Event 0 = restore; 1 = alarm/fault/trouble
Restore 0
Press [
✱
] to continue to the “Output Action” prompt
01 Output Action
Close for 2 sec 1
Output Action
0 = off
1 = Close for 2 seconds
2 = Stay Closed
3 = Pulse on & off (1 sec
ON, 1 sec OFF)
4 = Change Device State
5 = Duration 1 (see data
field *177)
6 = Duration 2 (see data
field *177)
Press [
✱
] to continue.
Enter the desired device action.
Enter Output No.
R02 02
Output Number
01-16 = FA168CPS outputs
01-08 = FA148CP outputs
17-18 = on-board triggers
Press [
✱
] to continue.
Enter the device output number (programmed in *79 Menu
Mode) you want associated with this output.
02 A E P TRIG
R02 1 1 3 ZL=00
Summary Screen
Press [
✱
] to continue.
A summary screen appears showing the programmed settings.
Press [∗] to return to OUTPUT FUNCTION NUMBER prompt
∗
∗∗
∗81 ZONE LIST MENU MODE
(press *81 while in Programming mode) The Zone List Worksheet is on page Error! Bookmark not defined..
Zone lists let you group individual zones for use with certain system actions. Using this mode, simply
select an appropriate
zone list number, then add the desired zone numbers to be included in that list.
The following table shows the available zone lists and their purposes:
List No. Used for… Notes
1, 2 general purpose (GP)
3 chime-by-zone (see field *26 to enable option)
4 cross zones (see note at right)
5 night stay zones
6 general purpose
SIA-Compliant: dial delay disable
7 general purpose
SIA-Compliant: unlimited reports
8 general purpose
9 zones that activate Pager 1
10 zones that activate Pager 2
11 zones that activate Pager 3 (FA168CPS)
12 zones that activate Pager 4 (FA168CPS)
• Any list may include any or all of the system's zone numbers.
• A zone list can be assigned to more than one output relay.
• Zone List 4: When creating zone list 4 for cross zoning,
include only zones assigned to zone types 3, 4, or 5. Do not
include zones that have delays (entry/exit zones, interior
w/delay) or 24-hour zones, as these zone types may produce
unpredictable operation and may not function as intended.
See field *85 for Cross Zone Timer option.
• Zone List 6: SIA-Compliant: See field *50 for Dial Delay Disable
option.
• Zone List 7: SIA-Compliant: See field *93 for Unlimited Reports
option.
*81 Menu Mode
Zone List No.
(00 = Quit) 01
Zone List Number
01-12 = zone list number
[∗] to continue
Enter the Zone List Number to program (or 00 to quit). Press [
✱
]
to advance.
In the following displays, zone list 01 has been selected.
01 Enter Zn Num.
(00 = Quit) 00
Zone Number
01-64
†
= zone numbers
followed by [∗] to
accept each zone
00 to continue
Enter each zone number to add to the zone list, followed by
pressing [
✱
] (example, 01
✱
, 02
✱
, 03
✱
). After all zones are
entered, press 00 to continue.
IMPORTANT: Do not include fire zones in zone lists that are
used to STOP device actions.
† FA168CPS = 01-64; FA148CP = 01-06, 09-34, 49-56.
01 Del Zn List?
0 = No 1 = Yes 0
Deleting Zone Lists
0 = don’t delete list
1 = delete this zone list
[∗] to continue
To delete the zone list, enter 1. All zones in the zone list will be
deleted automatically and the system returns to the Zone List
No. prompt.
To save the zone list, enter 0.