OPERATING YOUR APPLIANCE
Location and Use of Controls
NOTE: The Combustion Air Control and Combustor By-Pass Control become hot
during operation. Use a glove to adjust these controls while the appliance is
hot.
Combustion Air Control
The Combustion Air Control is located over the door on the right side and is operated by
sliding it from left to right. When the control is completely to the left, it is in the fully open
position. When it is completely to the right, it is in the fully closed position.
Combustor By-Pass Control
The Combustor By-Pass Control is located in the center of the faceplate above the door, and
is operated by pushing or pulling the control. When pulled out all the way, the catalytic
combustor is bypassed.
Blower Speed Control
The blower system is controlled by a thermostat located under the firebox which turns the
blower on automatically as the firebox heats up (approximately 45 minutes from start). The
blower will continue to run as long as the firebox has sufficient heat. Adjust the blower speed
by turning the control knob in the lower right corner of the fireplace face (see the illustration
below). For low heat range settings operate at the lowest setting and increase the air flow as
the heat range setting is increased by turning the control knob clockwise. The fireplace is
equipped with an automatic blower shut off switch to shut off the blower when the doors are
opened. The blower will always run as long as the firebox has sufficient heat and the doors
remain closed.
Arched Face Square Face
Combustor
By-Pass Control
Blower Speed Control
Combustion Air Control
Combustor
By-Pass Control
Combustion Air Control
Blower Speed Control