Logic AP - Logic AP (stepped automatic) is very similar to automatic (A) but has a higher
amount of safety. It has an increased amount of motion stop points.
Gate Status Result of Terminal
1 activation
Result of Terminal
2 activation
Result of Terminal
4 interruption
Result of Terminal
5 interruption
Closed
Opens leaf and re-closes after pause time No effect
Open and in
pause before
re-closing
Stops operation No effect Re-loads pause time
Closing
Re-opens leaf No effect Reverses direction of
motion
Opening
Stops operation Stops motion and
reverses direction
after interruption
No effect
Stopped in mid
cycle
Closes the leaf No effect
Logic EP - Logic EP (stepped semi-automatic) is designed to function similar to a garage door
opener. At full open the gate does not re-close after a pause time, it stays open until triggered to
re-close. Logic EP over-rides any set pause time.
Gate Status Result of Terminal
1 activation
Result of Terminal
2 activation
Result of Terminal
4 interruption
Result of Terminal
5 interruption
Closed
Opens leaf No effect
Open and in
pause before
re-closing
Re-closes the leaf
Closing
Stops operation No effect Reverses direction of
motion
Opening
Stops operation Reverses direction
of motion
No effect
Stopped in mid
cycle
Restarts motion in opposite direction the
gate was previously moving before
stopped in mid cycle
No effect
No effect
Gate Status Result of Termi-
nal 1 activation
Result of Termi-
nal 2 activation
Result of Termi-
nal 4 interruption
Result of Terminal
5 interruption
Result of Terminal
4&5 interrupted
simultaneous
Closed
Opens leaf and re-closes after pause time No effect
Open and in
pause before
re-closing
Stops operation No effect Re-loads pause time
Closing
Re-opens leaf No effect Reverses direction of motion
Opening
Stops operation Stops motion and
reverses direction
after interruption
No effect Reverses direction
of motion
Stopped in
mid cycle
Closes the leaf No effect
Gate Status Result of Termi-
nal 1 activation
Result of Termi-
nal 2 activation
Result of Termi-
nal 4 interruption
Result of Terminal
5 interruption
Result of Terminal
4&5 interrupted
simultaneous
Closed
Opens leaf No effect
Open and in
pause before
re-closing
Re-closes the leaf No effect
Closing
Stops operation No effect Reverses direction of motion
Opening
Stops operation Reverses direction
of motion
No effect Reverses direction
of motion
Stopped in
mid cycle
Restarts motion in opposite direction the
gate was previously moving before
stopped in mid cycle
No effect