Diagnostics using the Power light on your Master Control
Board.
The P light has a diagnostic function. There are 4 statuses.
1. Steady light indicating main power is ON and
the battery is charged
2. Flashing slowly (lights every second) indicates no main
power but the battery is charged.
3. Flashing quickly (lights every 1/4 of a second)
indicates main power on but discharged battery
4. Light OFF indicates no main power and discharged
battery.
Status of accessory inputs.
The Master Control Board has the ability to verify the status of the terminal board inputs. To ac-
cess this function:
When all LEDs are off (both lettered and numbered) press P2. The statuses of the accessory ter-
minals in the following chart will be shown in the lettered LEDs column.
LED ON =
Closed Contact
LED OFF =
Open Contact
When you have
finished checking,
press P2 again to
exit.
If you do not, the
LED status check
will stay active for
5 minutes and then
the board returns
to all LEDs OFF.
WARNING:
When you access
the input status
function all accessories are powered, even with the gate idle. P1 is active and can be used to
open and close the gate.
)
Normal Operation
idle LED lights
LED ON OFF
A = OFF A = Terminal 1,
Open/close function
Opening/closing
device is triggered.
Opening/Closing de-
vice is not triggered.
B = OFF B = Terminal 2, Sin-
gle leaf open/close
Opening/closing
device is triggered.
Opening/Closing de-
vice is not triggered.
C = ON C = Terminal 3,
Stop Command
Motion stop device is
in place and not
triggered or jumper is
in place..
Motion stop device
has been triggered or
is not connected.
D = ON D = Terminal 4,
Opening safety de-
vice
Motion stop device is
in place and not
triggered or jumper is
in place..
Safety device has
been triggered or is
not connected.
E = ON E = Terminal 5,
Closing safety de-
vice
Motion stop device is
in place and not
triggered or jumper is
in place..
Safety device has
been triggered or is
not connected.
1 = OFF if single
ON if dual
1 = Terminal 6,
Slave Board
Slave Board is
connected.
Slave board is not
connected.