Envision Peripherals Series Heat Pump User Manual


 
9
NS SPLIT INSTALLATION MANUAL
Air Handler Coil Data
Line Set Sizes
1]WZAc`TOQS
/`SOa_Tb
4>7 @]ea
BcPS
2WO[SbS`
#&! ! !&
#&! !&
;ObQVW\U/W`
6O\RZS`
</6"&$
</6 $!$
3\dWaW]\
A^ZWb;]RSZ
 $!&
"'%
Unit Air Factory
Size Handler
Suction Liquid Suction Liquid Suction Liquid
Charge (oz.)
NDS026 NAH026 5/8" OD 3/8" OD 3/4" OD 3/8" OD 3/4" OD 1/2" OD 52
NDS038 NAH036 5/8" OD 3/8" OD 3/4" OD 3/8" OD 3/4" OD 1/2" OD 56
NDS049 NAH048 3/4" OD 3/8" OD 7/8" OD 3/8" OD 7/8" OD 1/2" OD 90
NDS064 NAH060 7/8" OD 1/2" OD 7/8" OD 1/2" OD 1-1/8" OD 1/2" OD 92
NDS072 NAH060 7/8" OD 1/2" OD 7/8" OD 1/2" OD 1-1/8" OD 1/2" OD 104
Notes: Lineset charge for R410A is 0.50 oz. per ft. for 3/8" and 1.0 oz. per ft. for 1/2" tube. Rev.: 4/1/08
Initial Total System Charge = Factory Split charge + lineset charge + 20 oz, then adjust charge by subcooling and superheat measurements.
20 feet 40 feet 60 feet
Air Handler Nomenclature
</6 !$ / @
;]RSZBg^S /W`1]WZ
</6+3\dWaW]\/W`6O\RZS` @+@ST`WUS`O\b
6+6gR`]\WQ
C\Wb1O^OQWbg
@ST`WUS`O\b;]RSZa <][14; ;]b]`
 ;0BC6 & +31; & !$
 $;0BC6 ' #
!;0BC6 '&
!$;0BC6  #
" ;0BC6 " # 2WaQ]\\SQb
"&;0BC6 $ # +<]P`SOYS`W\abOZZSROdOWZOPZS]\#YEYEVSObS`a
$;0BC6 %$ +0`SOYS`W\abOZZSROdOWZOPZS]\#YE YEVSObS`a
6gR`]\WQ;]RSZa
 $;0BC6 ' #
!$;0BC6  # 3ZSQb`WQ6SOb
"&;0BC6 $ # +<]SZSQb`WQVSOb
$;0BC6 %$ #+#YEOdOWZOPZS]\ !$
+YEOdOWZOPZS]\!$
DW\bOUS #+#YEOdOWZOPZS]\" $
/+1c``S\b  + YEOdOWZOPZS]\$]\Zg