Initial Installation
QUALIFIED INSTALLERS ONLY
CONVERTING A DIRECT VENT FIREPLACE TO A B-VENTED FIREPLACE:
existing and attach with three (3) sheet metal screws evenly spaced to new 4’’ chimney connector.
5. Test re the appliance and ensure proper operation. A venturi adjustment could be required to achieve
an efcient ame. Improper operation or adjustment could result in Carbon Monoxide production
causing personal injury or property damage.
CONVERTING A B-VENT FIREPLACE TO A DIRECT VENTED FIREPLACE:
Chimney
Connector
Drafthood
Diverter
300°F (140°F)
Spill Switch
Air Channels (x2)
Parts required for conversion
1 - 300°F (149°C) manual reset spill switch
and wires
1 - Drafthood (4’’ chimney connection)
2 - Air channels
1 - Drafthood diverter
1. Remove the chimney connector, fresh air
cover plates and draft hood cover plate.
2. Install the 300°F (149°C) spill switch in the
location provided.
3. Install the two fresh air channels in the
correct locations.
4. Install a new 4’’ chimney liner into the
Drafthood
Cover Plate
Chimney
Connector
Air Channel
Cover Plate (x2)
Parts required for conversion
1 - Drafthood (2 - 3’’ dual pipe chimney
connector)
2 - Air channel cover plates
1 - Drafthood cover plate.
1. Remove the chimney connector, 300° spill
switch, two (2) B-vent air channels and B-
vent draft diverter plate.
2. Install the two (2) air channel cover plates in
the locations provided.
3. Install the draft hood cover plate in the
location provided.
4. Install two (2) 3’’ chimney liners in the
existing chimney, securing the 3’’ liners with
three (3) sheet metal screws evenly spaced
to the new chimney connector.
Figure 21: Converting To A BV Fireplace.
Figure 22: Converting To A DV Fireplace.
5. Test re the appliance and ensure proper operation. A venturi adjustment could be required to achieve
an efcient ame. Improper operation or adjustment could result in Carbon Monoxide production
causing personal or property damage.