Emerson CF2500S01 Fan User Manual


 
20. Securely attach the hanger bracket to the outlet
box using the two screws supplied with the outlet
box (Figure 27).
10
CEILING
FLOOR
AT LEAST
7'
Figure 26
TWO SCREWS
SUPPLIED WITH
OUTLET BOX
HANGER
BRACKET
TAB
OUTLET
BOX
Figure 27
19. Reinstall the switch housing assembly by passing the
wires from the motor shaft through the collar, screw
the assembly onto the motor shaft (Figure 24).
Tighten the setscrew using the 5/32” hex wrench
(supplied). Engage the connector from the switch
housing to the motor connector. The two connectors
are keyed and must be mated correctly before they
can be engaged (Figure 25).
MOTOR
CONNECTOR
SWITCH HOUSING
CONNECTOR
SWITCH HOUSING
ASSEMBLY
SETSCREW
COLLAR
Figure 25
21. Carefully lift the fan and seat the hanger
ball/downrod assembly on the hanger bracket that
was just attached to the outlet box (Figure 28). Be
sure the groove in the ball is lined up with tab on
the hanger bracket (Figure 27).
SWITCH HOUSING ASSEMBLY
SETSCREW
COLLAR
Figure 24
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked acceptable for
fan support, and use screws supplied with outlet
box. Most outlet boxes commonly used for support
of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified
electrician if in doubt.
WARNING
!
The outlet box must be securely anchored and capable
of withstanding a load of at least 50 lbs.
WARNING
!
The fan must be hung with at least 7' of clearance
from floor to blades (Figure 26).
WARNING
!
Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.
WARNING
!
Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.
WARNING
!
To reduce the risk of personal injury, do not bend the
blade flanges when installing the flanges, balancing
the blades, or cleaning the fan.
WARNING
!
18.The blade flanges have an interlocking feature that
must be fully engaged before tightening the
screws. Make sure all the flanges are properly
engaged and then tighten the flange screws In a
clockwise sequence. If one of the flanges does not
seat properly on the motor hub, loosen the
adjacent flange screws, re-engage and reseat the
flanges, then tighten the screws again.