Emerson 400508-02 Home Security System User Manual


 
14
FM-3 Programming Module Installation Manual
Encoder Hardware
If any pair of encoder lines are in the same state, an encoder line fault is generated. The most
likely cause is a missing or bad encoder connection.
Motor Overtemp
This fault is generated when the motor thermal switch is open due to motor over-temperature
or incorrect wiring.
RMS Shunt Power
This fault is generated when RMS shunt power dissipation is greater than the design rating of
the internal shunt.
Overspeed
This fault occurs when the actual motor speed exceeds the Overspeed Velocity Limit
parameter. This parameter can be accessed with PowerTools FM-3 software.
Max Following Error
This fault is generated when the following error exceeds the following error limit (default
following error limit is .2 revs). With PowerTools FM-3 you can change the Following Error
Limit value on disable in the Position view.
Travel Limit +/-
This fault is caused when either the + or - Travel Limit input function is active.
All "On"
This is a normal condition during power up of the drive. It will last for less than 1 second. If
this display persists, call EMERSON for service advice.