EarthStone woofire oven Indoor Fireplace User Manual


 
EARTHSTONE OVENS PRE-ASSEMBLED INSTALLATION INSTRUCTIONS---U.L. LISTED 17
Improper Installation (cont)
2) Oven is not closed to plenum/attic and is open to HVAC airflow.
Roof
Ceiling
Air flow
Air flow
Air flow
Installing a sealed enclosure around the oven
shell may cause improper operation by
starving the burner system of combustion air.
The air flow which travels above will cause
“negative pressure” below where the gas
burner is located. The air underneath will travel
towards the air flow above creating a suction
which will force the gas flame downwards. To
prevent this a non-combustable lid must be
placed above the oven.
3) Altered airflow from air intake in a separate room with low pressure.
Roof
Ceiling
Air flow
Air flow
Air Intake
Air Intake
Air flow
A
ir flow to oven is altered as air
moves from normal to low
pressure
Low pressure is created
by HVAC or any air moving
equipment outside oven
room
In this case the air intake located on the rear of the oven should be closed.