www.desatech.com
124183-01B14
GAS SHUTOFF
VALVE OPERATION
Adjust the ame ON/OFF by turning gas shut-
off valve counterclockwise to open or
clockwise to close, as necessary.
Shutting Off Appliance
Turn gas shutoff valve clockwise to
OFF position.
CURING
LOGS
During the 2-3 hour appliance break-in period,
you may detect an odor from the appliance
as various paints and compounds used in
manufacturing of this log set cure. This is a
normal and temporary situation that is not
cause for alarm. However, you may want to
provide extra ventilation to the room during
this time.
To ensure proper curing of the logs:
• Ignite a 2" ame and maintain it for 1
hour.
• Burn logs in consecutive 1 hour periods
raising the ame an additional 2" to full
ame height for a total of three hours.
OPERATING
INSTRUCTIONS
Note: Operation instructions for GA9050A-1
Remote Ready Valve/Pilot Kit will be included
with the kit.
1. STOP! Read the safety information,
column 1.
2. Make sure equipment shutoff valve is fully
open.
3. Press in and turn control knob clockwise
to the OFF position.
4. Wait ve (5) minutes to clear out any gas.
Then smell for gas around log set and
near oor. If you smell gas, STOP! Refer
to the National Fuel Gas Codes, ANSI
Z233.1/NFPA 54, Air for Combustion and
Ventilation. If you don’t smell gas, go to
the next step.
5. Turn control knob counterclockwise
to the PILOT position and press
in. Keep control knob pressed in for ve
(5) seconds.
OPERATION
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
-
-
WHAT TO DO IF YOU SMELL GAS
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information,
above.
2. Turn gas shutoff valve to OFF.
3. Wait ve (5) minutes to clear out any gas.
If you then smell gas STOP! Follow the
safety information, above. If you don't
smell gas, go on to the next step.
4. Light a match and lay it on top of pan
material about 2" from end of supply side
of pan
5. Slowly turn gas shutoff valve ON until
burner ignites. If burner doesn’t ignite
within 10 seconds with match burning,
turn shutoff valve OFF and repeat steps
1 through 4 again.