Desa T32N-A, CGDV32NR, T32P-A, CGDV32PR Indoor Fireplace User Manual


 
www.desatech.com
116646-01E6
PRE-INSTALLATION
PREPARATION
Continued
NOTICE: This replace is in-
tended for use as supplemental
heat. Use this replace along with
your primary heating system. Do
not install this replace as your
primary heat source. If you have a
central heating system, you may
run system’s circulating blower
while using replace. This will
help circulate the heat through-
out the house. In the event of a
power outage, you can use this
replace as a heat source.
FRAMING AND FINISHING
Figure 4 shows typical framing of this replace.
Figure 5 shows framing for corner installation. All
minimum clearances must be met.
For available accessories for this replace, see
Accessories on page 37. If you are using a separate
combustible mantel piece, refer to Figure 6 for
proper installation height. You can install noncom-
bustible mantels at any height above the replace.
Note: Noncombustible mantels may discolor!
32
3
/8"
34
5
/8"
17" Horiz. Vent
20" Vert. Vent
Figure 5 - Framing Clearances for Corner
Installation
A
B
E
F
G
H
D
C
Nailing Tabs
28
1
/
2
"
13
5
/
8
"
39
3
/
8
"
9
1
/
2
"
9
7
/
8
"
34
3
/
8
"
54
1
/
8
"
Nailing
Tabs
C
B
A
D
E
F
G
Top of Louver
Opening
3
2
1
4
5
6
7
Wall
Figure 6 - Clearances for Combustible
Mantels
34
5
/
8
"
Figure 4 - Framing Clearances for
Installation Against an Exterior Wall
Ref.
Mantel
Depth Ref.
Mantel from
Top of Louver
Opening
1 14" A 16"
2 12" B 14"
3 10" C 12"
4 8" D 10"
5 6" E 8"
6 4" F 6"
7 2" G 4"