Desa T32N-A, CGDV32NR, T32P-A, CGDV32PR Indoor Fireplace User Manual


 
www.desatech.com
116646-01E 31
CLEANING AND
MAINTENANCE
Continued
Use only the tempered glass door replacement
intended for this replace (see Replacement Parts,
page 36 for detail on ordering). No substitutions
may be made. See Removing/Replacing Glass Door,
page 23 for instructions for replacing glass door.
WARNING: Do not operate
replace with the glass door
unlatched, removed, cracked
or broken.
PILOT AND BURNERS
Remove ember material before cleaning burners
and replace when cleaning is complete.
Burner and controls should be cleaned with
compressed air to remove dust, dirt or lint.
Use a vacuum cleaner or small, soft bristled
brush to remove excess dust, dirt or lint.
LOGS
If you remove logs for cleaning, refer to In-
stalling Logs, Lava Rock and Glowing Embers,
page 23, to properly replace logs.
Use a vacuum cleaner to remove any carbon
buildup on logs.
Replace log(s) if broken. See Replacement
Parts on page 36.
Replace ember material periodically as needed.
See Replacement Parts on page 36.
VENTING SYSTEM
Conduct annual inspection of the venting system
following these guidelines:
1.
Check areas of venting system that are exposed to
the weather for corrosion (rust spots or streaks and,
in extreme cases, holes). Have these items replaced
immediately by a qualied service person.
2. Remove the vent cap and shine a ashlight
into the vent. Remove any foreign material.
3. Check for evidence of excessive condensation.
Continuous condensation can cause corrosion
of caps, pipes and ttings and can be caused
by having excessive lateral runs, too many
elbows or exterior portions of the system being
exposed to cold weather.
4. Inspect joints to verify that no pipe section or
tting has been disturbed and loosened. Check
mechanical supports such as wall straps for
rigidity.