Desa VC36N Indoor Fireplace User Manual


 
www.desatech.com
116200-01L 5
PRODUCT FEATURES
Figure 2 - Common Fireplace Locations
Figure 3 - Fireplace Bottom Dimensions
D
RW
FW
29"
41"
PRE-INSTALLATION PREPARATION
LOCAL CODES
Install and use replace with care. Follow all
local codes. In the absence to local codes,
use the current National Fuel Gas Code ANSI
Z223.1/NFPA 54* (USA) or the current CSA-
B149.1 Installation Code (Canada).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
These are a few facts that can help you under-
stand and enjoy your direct-vent replace:
The venting system may be routed to the
outside of your home in several ways. It
may vent through the roof (vertical) or it
may vent to an outside/exterior wall (hori-
zontal). The vent pipe installation is very
important to allow for proper operation.
You must follow the venting instructions
very carefully for either vertical or horizontal
applications.
This replace may be installed in any room
of your house provided all local codes and
these installation instructions are followed.
This replace requires a wall switch, hand-
held remote or wall thermostat (millivolt) for
operation (see Accessories, page 42).
This replace does not require electricity
to operate.
Only the blower requires electricity if in-
stalled and if you plan to install the blower at
a later date, do not forget to wire the outlet at
the bottom of the replace when framing.
A piezo ignitor and ceramic electrode cre-
ate spark to ignite the pilot light. It does not
require any matches, batteries or any other
sources of ignition to light the pilot.
Each time you turn on your replace, you
may notice some amount of condensation
on the inside of the replace glass. This
is normal and will disappear after 10-20
minutes of operation.
Your direct-vent gas fireplace system
(replace and venting) is a balanced and
sealed gas operating unit. It requires ap-
proximately 10-20 minutes of operating
time before the ame pattern stabilizes.
Fireplaces with the sufx of -HA have been
designed to operate at altitudes of 4000
feet and above.
LOCATION AND SPACE
REQUIREMENTS
Determine the safest and most efcient loca-
tion for your DESA Heating, LLC direct-vent
replace. Make sure that rafters and wall
studs are not in the way of the venting system.
Choose a location where the heat output is
not affected by drafts, air conditioning ducts,
windows or doors. Figure 2 shows some com-
mon locations. Be aware of all restrictions and
precautions before deciding the exact location
for your replace and termination cap.
When deciding the location of your replace,
follow these rules:
Do not connect this replace venting to a
chimney ue serving a separate solid-fuel
burning replace or appliance.
Due to high temperatures, do not locate this
replace in high trafc areas, windy or drafty
areas or near furniture or draperies.
Proper clearances must be maintained.
Flush with a wall
Through exterior wall
enclosed in a chase
Corner
installation
21