Desa VC36N Indoor Fireplace User Manual


 
www.desatech.com
116200-01L30
OPERATING OPTIONAL
GWMT1 - WALL MOUNTED
THERMOSTAT
WARNING: Do not con-
nect the thermostat to a power
source. Electrical shock and/or
a re hazard will occur.
Light replace as instructed in Lighting In-
structions on page 27. Set wall thermostat to
desired temperature.
This thermostat has been electronically cali-
brated at the factory and requires no adjust-
ment or leveling.
Upon installation, thermostat must be allowed
to stabilize at room temperature for a mini-
mum of 30 minutes for proper operation.
To turn replace off, adjust thermostat to the
lowest setting and turn gas control knob back
to PILOT. The pilot will remain lit.
IMPORTANT: To turn pilot off, turn gas control
knob on heater to the OFF position.
OPERATION
Continued
INSPECTING BURNERS
Thermocouple
Thermopile
1/8"
Pilot Burner
Piezo
Ignitor
Figure 49 - Pilot Assembly
3/8" to 1/2"
OPERATING OPTIONAL
BLOWER ACCESSORY
Locate blower controls by opening lower
louver panel on replace. Blower controls are
located on the right side of switch bracket to
the left just inside louver panel.
The BK manual blower and BKT thermostati-
cally-controlled blower have an ON setting
and an OFF setting. Blower will only run when
switch is in the ON position. In the OFF posi-
tion, blower will not operate.
Note for BKT Only: If you are using BKT
blower with optional thermostat (wall mounted
or remote control) for replace, your replace
and blower will not turn on and off at the same
time. Fireplace may run for several minutes
before blower turns on. After heater modulates
to the pilot position, blower will continue to run.
Blower will shut off after rebox temperature
decreases.
The blower helps distribute heated air from the
replace. Periodically check louvers of rebox
and remove any dust, dirt or other obstruc-
tions that will hinder the ow of air.
Check pilot ame pattern and burner ame
patterns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the
proper ame height. Alterations may have
occurred during shipping and handling. Call
a qualied service person to readjust the pilot
if necessary.
The height of thermopile must be 3/8" to 1/2"
above pilot ame as shown in Figure 49. The
thermocouple must be at a height of about
1/8" above pilot ame. Flame from pilot burner
must extend beyond both thermocouple and
thermopile.
If you pilot assembly does not meet these
requirements:
turn replace off (see To Turn Off Gas to
Appliance, page 28)
see Troubleshooting, page 33