Desa PORTABLE FORCED AIR HEATERS Electric Heater User Manual


 
6
104252
PORTABLE FORCED AIR HEATER
70,000 AND 100,000 BTU/HR
PREVENTATIVE
MAINTENANCE
SCHEDULE
Item
Fuel tank
Air output and lint filters
Air intake filter
Fuel filter
Spark plug
Fan blades
Motor
WARNING: Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.
STORING,
TRANSPORTING,
OR SHIPPING
Note:
If shipping, transport companies re-
quire fuel tanks to be empty.
1. Drain fuel tank.
Note:
Some models have drain plug on
underside of fuel tank. If so, remove
drain plug to drain all fuel. If heater
does not have drain plug, drain fuel
through fuel cap opening. Be sure all
fuel is removed.
2. Replace drain plug if provided.
3. If any debris is noted in old fuel, add 1
or 2 quarts of clean kerosene to tank,
stir, and drain again. This will prevent
excess debris from clogging filters dur-
ing future use.
4. Replace fuel cap or drain plug. Prop-
erly dispose of old and dirty fuel. Check
with local automotive service stations
that recycle oil.
5. If storing, store heater in dry place.
Make sure storage place is free of dust
and corrosive fumes.
IMPORTANT:
Do not store kerosene over
summer months for use during next heating
season. Using old fuel could damage heater.
OPERATION
WARNING: Review and un-
derstand the warnings in the
Safety Information Section. They
are needed to safely operate this
heater. Follow all local codes
when using this heater.
To Start Heater
1. Follow all ventilation and safety infor-
mation.
2. Fill fuel tank with kerosene or No. 1
fuel oil.
3. Attach fuel cap.
4. Plug power cord of heater into standard
230 volt/50 hertz, grounded (earthed)
outlet. Use an extension cord if needed.
Use only a grounded (earthed) exten-
sion cord.
Extension Cord Wire Size Re-
quirements
Up to 100 feet (30.5 meters) long, use
16 AWG (1.0 mm
2
) conductor
101 to 200 feet (30.6 to 61 meters) long,
use 14 AWG (1.5 mm
2
) conductor
5. Switch heater on.
How Often
Flush every 150-200 hours of operation or as needed.
Replace every 500 hours of operation or once a year.
Wash and dry with soap and water every 500 hours of
operation or as needed.
Clean twice a heating season or as needed.
Clean and regap every 300 hours operation or replace
as needed.
Clean every season or as needed.
Not required/permanently lubricated
How To
See Storing, Transporting, or Shipping, above.
See Air Output, Air Intake, and Lint Filters,
page 9.
See Air Output, Air Intake, and Lint Filters,
page 9.
See Fuel Filter, page 8.
See Spark Plug, page 8.
See Fan, page 12.
To Stop Heater
1. Switch heater off. Unplug power cord
from outlet.
To Restart Heater
1. Wait 2 minutes after stopping heater.
2. Repeat steps under To Start Heater.