Installation Items Needed
Before installing log set, make sure you have
the items listed below.
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve*
• test gauge connection*
• adjustable (crescent) wrench or pliers
• sediment trap
• tee joint
• pipe wrench
• exible gas line
* A CSA design-certied equipment shutoff
valve with 1/8" NPT tap is an acceptable al-
ternative to test gauge connection. Purchase
the optional CSA design-certied equipment
shutoff valve from your dealer.
For propane/LP units, the installer must
supply an external regulator. The external
regulator will reduce incoming gas pressure.
You must reduce incoming gas pressure
to between 11" and 14" of water. If you do
not reduce incoming gas pressure, heater
regulator damage could occur. Install exter-
nal regulator with the vent pointing down as
shown in Figure 2, page 3. Pointing the vent
down protects it from freezing rain or sleet.
WARNING: Never connect
CAUTION: Use only new,
-
INSTALLATION
Continued
Installation must include an equipment shutoff
valve, union and plugged 1/8" NPT tap. Locate
NPT tap within reach for test gauge hook up.
NPT tap must be upstream from log set (see
Figure 3, page 4).
IMPORTANT: Install equipment shutoff valve
in an accessible location. The equipment
shutoff valve is for turning on or shutting off
the gas to the appliance.
Check your building codes for any special
requirements for locating equipment shutoff
valve to appliance.
Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from
going into pipe. Excess sealant in pipe could
result in a clogged burner orice.
We recommend that you install a sediment
trap in supply line as shown in Figure 3,
page 4. Locate sediment trap where it is
within reach for cleaning. Install in piping
system between fuel supply and heater.
Locate sediment trap where trapped matter
is not likely to freeze. A sediment trap traps
moisture and contaminants. This keeps
them from going into log set controls. If
sediment trap is not installed or is installed
wrong, log set may not run properly.
Figure 2 - External Regulator on
Propane/LP Supply Tank with Vent
Pointing Down
External
Regulator
Vent
Pointing
Down
Propane/LP
Supply Tank